Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(8)
Fujitsu Atlantic
(7)
GENERAL
(7)
GREE
(0)
GSS
(0)
HAIER
(2)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(1)
IVT
(0)
Inventor
(1)
KAYSUN
(0)
LG
(21)
MIDEA
(0)
MITSUBISHI ELECTRIC
(13)
Mitsubishi Heavy Industries
(68)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(5)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 | |
|
FDC100VNA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VNX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.18 | 4.18 | -20° | 10.00 | 11.20 | |
|
FDC250VSA/FDE125VH/FDE125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.45 | 3.58 | 24.00 | 14.20 | ||
|
FDC100VNA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.84 | 4.17 | 4.18 | -20° | 10.00 | 11.20 | |
|
FDC250VSA/FDF125VD/FDF125VD
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.45 | 4.25 | 3.18 | 24.00 | 14.20 | ||
|
FM48AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM49AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM48AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM49AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FDC100VNX/FDU100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VNX/FDUM100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VNX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VSX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VSX/FDU100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.19 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VSX/FDUM100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.19 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC140VNA/FDF140VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.10 | 4.17 | 3.11 | 13.00 | 10.50 | ||
|
FDC125VNA/FDU125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA/FDU125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC140VSA/FDF140VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.03 | 4.17 | 3.11 | 13.60 | 10.50 | ||
|
FDC125VNA/FDUM125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
AOYG36LATT/ARYG36LMLA
ARY**L
|
FUJITSU | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.90 | -15° | 10.00 | 10.00 | |
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOHG90LRLA/ARHG90LHTA
AOHG**L
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
ROG90LRLA/RDG90LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
FDC100VNX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.92 | 4.16 | 3.20 | -20° | 10.00 | 11.20 | |
|
FDC100VNA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
FDC125VNA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC125VSA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC140VNA/FDE140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.15 | 3.51 | 13.60 | 10.50 | ||
|
FDC140VSA/FDE140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.15 | 3.51 | 13.60 | 10.50 | ||
|
FDC140VNA/FDU140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.08 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA/FDUM140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.08 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VNA/FDUM140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.08 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA/FDU140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.08 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC125VNA/FDF125VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.96 | 3.38 | 12.50 | 9.80 | ||
|
FDC100VNA/FDUM50VH/FDUM50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.94 | 3.49 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM50VH/FDUM50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.94 | 3.49 | -20° | 10.00 | 8.50 | |
|
FDC125VSA/FDF125VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.96 | 3.38 | 12.50 | 9.80 | ||
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 |