Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(8)
ATLANTIC
(0)
AUX
(7)
BOSCH
(10)
BRYANT
(0)
Buderus
(0)
CARRIER
(14)
CIAT
(7)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(2)
DAIKIN
(45)
EQUATION
(0)
FUJI ELECTRIC
(16)
FUJITSU
(43)
Fujitsu Atlantic
(20)
GENERAL
(22)
GREE
(7)
GSS
(0)
HAIER
(12)
HEC
(2)
HEIWA
(0)
HISENSE
(40)
HITACHI
(16)
IVT
(0)
Inventor
(8)
KAYSUN
(8)
LG
(48)
MIDEA
(40)
MITSUBISHI ELECTRIC
(75)
Mitsubishi Heavy Industries
(65)
NORD
(2)
Nobu
(0)
PANASONIC
(66)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(1)
THERMOR
(2)
TOSHIBA
(29)
Viessmann
(1)
Vulcano
(2)
WESTPOINT
(1)
YORK
(7)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-36PZH3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.50 | 4.17 | -20° | 3.60 | 3.60 | |
|
RAV-GP1101AT-E/RAV-HM1101FT-E
SDI
|
TOSHIBA | Floor standing | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.40 | 4.06 | -27° | 10.00 | 9.20 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAC-VJ35NHAE / RAD-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.70 | |
|
FDC71VNX-W/FDU71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.47 | 4.49 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDUM71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.45 | 4.49 | -20° | 7.10 | 6.00 | |
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
RAV-GP561ATW-E/RAV-HM561CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.93 | 4.73 | 4.03 | -27° | 5.00 | 3.80 | |
|
AUW40U4RJ8/ADT40UX4RCL8
Turbo Inverter R32
|
HISENSE | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 4.30 | -10° | 4.10 | 4.00 | |
|
AUW52U4RJ8/ADT52UX4RCL8
Turbo Inverter R32
|
HISENSE | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 4.15 | -10° | 5.00 | 4.00 | |
|
PUZ-ZM100VDA/PEAD-M100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PEAD-M100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PEAD-M100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PEAD-M100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
AUW35U4RS8/ADT35UX4RBL8
Turbo Inverter R32
|
HISENSE | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 4.00 | -10° | 3.50 | 3.00 | |
|
PUZ-ZM100YDA/PEAD-M100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA/PEAD-M100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PEAD-M100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 4.40 | -20° | 9.50 | 7.80 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.92 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
AUW40U4RS7/ADT40UX4RCL8
Turbo Inverter R32
|
HISENSE | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 4.11 | -10° | 4.10 | 4.00 | |
|
FDC90VNP-W/FDE100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.78 | 4.46 | 4.52 | -15° | 9.00 | 5.80 | |
|
U-60PZ3E5A / S-6071PF3E
2021
|
PANASONIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.04 | -15° | 5.70 | 4.40 | |
|
AUW105U6RN8/AUD105UX4REH8
Turbo Inverter R32
|
HISENSE | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.40 | 4.00 | -10° | 10.00 | 8.00 | |
|
FDC100VNX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
PUZ-ZM50VKA2/PEAD-M50JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA2/PEAD-M50JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PEAD-M50JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PEAD-M50JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.40 | -11° | 5.00 | 3.80 | |
|
FDC200VSA-W/FDUM100VH/FDUM100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.57 | 4.64 | 4.01 | 20.00 | 12.50 | ||
|
RAV-GM902ATW-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.75 | 4.30 | 4.00 | -15° | 8.00 | 6.30 | |
|
UUC1 U40 / UM24FH N20
U4
|
LG | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.30 | 4.28 | -10° | 6.80 | 5.40 | |
|
RAV-GP1101AT8-E/RAV-HM1101CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.23 | 4.46 | -20° | 10.00 | 11.60 | |
|
AOYG09KBTB/ARXG09KLLAP
ARY**K
|
FUJITSU | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/ARXG09KLLAP
ARH**K
|
GENERAL | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RDG09KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/ARXG09KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
5MWXM90A9 / FBA100A
5MWXM
|
DAIKIN | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.22 | 4.21 | -15° | 8.70 | 6.46 | |
|
FDC100VNA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
PUZ-ZM71VHA2/PEAD-M71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA2/PEAD-M71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
U-71PZ3E5A / S-6071PU3E
2021
|
PANASONIC | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.60 | 4.23 | -15° | 7.10 | 5.20 | |
|
FDC100VNX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 |