Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(11)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(12)
MIDEA
(0)
MITSUBISHI ELECTRIC
(4)
Mitsubishi Heavy Industries
(5)
NORD
(0)
Nobu
(0)
PANASONIC
(5)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(1)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC90VNP-W/FDE100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.78 | 4.46 | 4.52 | -15° | 9.00 | 5.80 | |
|
FDC90VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDUM100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
U-100PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 4.93 | -15° | 10.00 | 10.00 | |
|
U-100PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.93 | -15° | 10.00 | 10.00 | |
|
RAV-GM401ATP-E/RAV-HM401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.34 | 5.10 | 5.13 | -15° | 3.60 | 2.70 | |
|
PUZ-ZM35VKA2/PEAD-M35JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/PEAD-M35JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
ARXP20N / ATXP20N
ARXP
|
DAIKIN | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.64 | 4.77 | -15° | 2.00 | 2.20 | |
|
ARXP20N9 / ATXP20N9
ARXP
|
DAIKIN | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.64 | 4.77 | -15° | 2.00 | 2.20 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
SRC25ZTL-W/SRK25ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.70 | 4.55 | -10° | 2.50 | 2.70 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
MXZ-2D42VA2/MSZ-EF18VE3W(B)(S)/MSZ-EF25VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.84 | -15° | 4.20 | 3.20 | |
|
U-25PZ3E5/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 4.52 | -15° | 2.50 | 2.50 | |
|
SRC15ZTL-W/SRK15ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.40 | 4.76 | -10° | 1.50 | 2.30 | |
|
RZASG100MV1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
38QUS014D8S2-1/42QHE07D8SH*
Wall mounted
|
CARRIER | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 4.00 | 4.65 | -10° | 4.10 | 3.80 | |
|
RZASG100MV1 / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | 4.81 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | 4.81 | -10° | 9.50 | 6.00 | |
|
PC09SC UA3T / PC09SC NSJT
UA3
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.52 | -10° | 2.50 | 2.50 | |
|
PZ09EYN CSJ1 / PZ09EYU CA31
U12A
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.52 | -10° | 2.50 | 2.50 | |
|
PZ09NYN CSJ1 / PZ09NYU CA31
U12A
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.52 | -10° | 2.50 | 2.50 | |
|
EZ09CYN CSJ1 / EZ09CYU CA31
U12A
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.52 | -10° | 2.50 | 2.50 | |
|
EZ09CSN CSJ1 / EZ09CSU CA31
U12A
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.52 | -10° | 2.50 | 2.50 | |
|
PZ09EYN ASJ1 / PZ09EYU AA31
U12A
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.52 | -10° | 2.50 | 2.50 | |
|
EZ09CYN ASJ1 / EZ09CYU AA31
U12A
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.52 | -10° | 2.50 | 2.50 | |
|
DZ09RTK ASJ1 / DZ09RTK AA31
U12A
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.52 | -10° | 2.50 | 2.50 | |
|
PZ09AYN ASJ1 / PZ09AYU AA31
U12A
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.52 | -10° | 2.50 | 2.50 | |
|
RZASG100MV1 / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | 4.77 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | 4.77 | -10° | 9.50 | 6.00 | |
|
UUA1 UL0 / MJ09PC NSJ
UU
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.50 | -10° | 2.50 | 2.80 | |
|
UUA1 UL0 / MJ09PC NSJ0
UU
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.50 | -10° | 2.50 | 2.80 | |
|
S09ETK NSJS / S09ETK U12S
U12A
|
LG | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 7.00 | 3.80 | 4.52 | -10° | 2.50 | 2.50 | |
|
AZAS100MV1 / FBA100A
AZAS
|
DAIKIN | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | 4.77 | -10° | 9.50 | 6.00 | |
|
AZAS100MY1 / FBA100A
AZAS
|
DAIKIN | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | 4.77 | -10° | 9.50 | 6.00 | |
|
AZAS100MV1 / ADEA100A
AZAS
|
DAIKIN | Ducted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.13 | 3.81 | 4.63 | -10° | 9.50 | 6.00 |