Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(57)
ATLANTIC
(17)
AUX
(66)
BOSCH
(55)
BRYANT
(5)
Buderus
(16)
CARRIER
(89)
CIAT
(34)
COLIBRI
(3)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(475)
EQUATION
(2)
FUJI ELECTRIC
(109)
FUJITSU
(287)
Fujitsu Atlantic
(140)
GENERAL
(139)
GREE
(62)
GSS
(3)
HAIER
(401)
HEC
(5)
HEIWA
(4)
HISENSE
(202)
HITACHI
(99)
IVT
(0)
Inventor
(98)
KAYSUN
(61)
LG
(294)
MIDEA
(519)
MITSUBISHI ELECTRIC
(443)
Mitsubishi Heavy Industries
(281)
NORD
(36)
Nobu
(7)
PANASONIC
(188)
RIELLO
(37)
Rotenso
(8)
SAMSUNG
(117)
THERMOR
(32)
TOSHIBA
(203)
Viessmann
(21)
Vulcano
(14)
WESTPOINT
(3)
YORK
(35)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC140VSX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.15 | 3.22 | 14.00 | 14.30 | ||
|
FDC71VNX-W/FDE40VH/FDE40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.48 | 4.49 | 3.81 | -20° | 7.10 | 6.00 | |
|
FDC140VNX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.15 | 3.22 | 14.00 | 13.00 | ||
|
AC100RXADKG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.61 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.69 | -20° | 10.00 | 5.30 | |
|
PUZ-ZM100VDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.43 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.43 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.43 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.43 | 12.10 | 6.00 | |||
|
FDC71VNX-W/FDTC40VH/FDTC40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.37 | -20° | 7.10 | 6.00 | |
|
RXM35R9 / FCAG35B
RXM
|
DAIKIN | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.90 | 3.77 | -15° | 3.50 | 3.32 | |
|
U-71PZH4E5 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-250PZH4E8 + P‐VTVF250NC5‐PE
2025
|
PANASONIC | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-250PZH4E8 + P‐VTVF250PC5‐PE
2025
|
PANASONIC | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
FDC200VSA-W/FDE100VH/FDE100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.53 | 3.96 | 20.00 | 12.50 | ||
|
MOX430U-24HFN8-QRD1W(GA)/MTJ-24HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-QRD1W/MTJ-24HWFNX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(GA)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MO-24N8-Q-1/MTJU-24NX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
KUE-71 DVR14/KPD-71 DR15
Duct R32
|
KAYSUN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-QRD1W(GA)-GR/MTJ-24HWFNX-QRD1W(GA)-GR
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
DDMD-070N-09M25/YDAX-070H-09M25**
DDMD
|
AIRWELL | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
42QSV024D8S*/38QUS024D8SX*
Ducted
|
CARRIER | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
Vitoclima100-SIDHAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ducted
|
Viessmann | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
U7iRS-24/V7iDI-24WiFiR
Ducted R32
|
Inventor | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(H)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
RAS-4HVRC2E / RCI-4.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.93 | 4.36 | 4.23 | -20° | 10.00 | 8.70 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RCG09KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
U-25PZ3E5 / S-25PY3E
2022
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -15° | 2.50 | 2.80 | |
|
U-125PZH4E5 / S-2545PK4E(4x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E8 / S-2545PK4E(4x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
RAS-2M60S4AVG-ND/RAS-B25G3KVSG-ND+RAS-B35S4KVPG-ND
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.60 | 3.74 | -25° | 6.00 | 6.50 | |
|
U-100PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 4.93 | -15° | 10.00 | 10.00 | |
|
RAS-4HVNC2E / RCI-4.0FS1R
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.40 | 4.30 | -20° | 10.00 | 8.70 | |
|
RAV-GM1102AT8W-E/RAV-HM1101CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.46 | 4.29 | 3.95 | -15° | 9.50 | 8.00 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.42 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.42 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.42 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.42 | 12.10 | 6.00 | |||
|
RAV-GM901ATP-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 |