Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(14)
BRYANT
(0)
Buderus
(4)
CARRIER
(21)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(56)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(20)
Fujitsu Atlantic
(8)
GENERAL
(28)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(76)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(0)
MIDEA
(33)
MITSUBISHI ELECTRIC
(244)
Mitsubishi Heavy Industries
(116)
NORD
(0)
Nobu
(0)
PANASONIC
(143)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(92)
THERMOR
(0)
TOSHIBA
(124)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(0)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAC-XJ50WHBE / RAK-XJ50RHBE
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAC-XJ50WHBE / RAK-XJ50RHBEG
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
U-50PZH3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.37 | -20° | 4.70 | 4.50 | |
|
CL8100i 65 E / CL8100i-W 65 E
Climate 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.75 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HE
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HET
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HES
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HER
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
MUZ-LN50VGHZ2/MSZ-LN50VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.05 | -25° | 5.00 | 6.00 | |
|
MUZ-LN50VGHZ3/MSZ-LN50VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.05 | -25° | 5.00 | 6.00 | |
|
PUZ-ZM125YDA/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
RXTP35A / FTXTP35A
RXTP
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 4.85 | 4.55 | -30° | 3.50 | 3.00 | |
|
ARXM35R9 / ATXM35R
ARXM
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 5.10 | 4.04 | -20° | 3.40 | 2.50 | |
|
RXTP35A / FTXTP35N
RXTP
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 4.85 | 4.55 | -30° | 3.50 | 3.00 | |
|
ARXM50R / ATXM50R
ARXM
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.65 | 3.79 | -20° | 5.00 | 4.60 | |
|
U-60PZH3E5 / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.80 | 4.19 | -20° | 6.10 | 4.60 | |
|
RAC-50WXEN / RAK-50RXE
RAC-WXEN
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
CU-NZ35YKE / CS-NZ35YKE
2023
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
CU-NZ35YKE / CS-NZ35YKE-1
2024
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
RXM42R / FTXM42R
RXM
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.85 | 4.71 | 4.12 | -20° | 4.20 | 4.00 | |
|
AC035BXAPKG/AC035BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | 3.81 | -25° | 3.50 | 2.30 | |
|
PUZ-ZM140VDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
FDC100VNX-W/SRK50ZSX-W/SRK50ZSX-W
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.66 | 4.25 | 4.31 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/SRK50ZSX-W/SRK50ZSX-W
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.66 | 4.25 | 4.31 | -20° | 10.00 | 11.20 | |
|
ARXM50A8 / ATXM50A
ARXM
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.70 | 3.90 | -20° | 5.00 | 4.50 | |
|
U-36PZH3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.40 | 4.90 | 4.82 | -20° | 3.60 | 3.60 | |
|
U-125PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.04 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
MUZ-AY25VG/MSZ-AY25VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.10 | -20° | 2.50 | 2.40 | |
|
CU-Z20ZKE / CS-Z20ZKEW
2023
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
CU-Z20ZKE / CS-XZ20ZKEW
2023
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
CU-Z20ZKE / CS-XZ20ZKEW-H
2023
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
MUZ-AY25VG2/MSZ-AY25VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.10 | -20° | 2.50 | 2.40 | |
|
CU-Z20CKE / CS-Z20CKEW
2025
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
CU-Z20CKE / CS-XZ20CKEW
2025
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
CU-Z20CKE / CS-XZ20CKEW-H
2025
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
U-140PZH4E5 / S-1014PU3E
2023
|
PANASONIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.24 | 4.61 | 4.30 | -20° | 13.40 | 10.60 | |
|
U-125PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
PUZ-ZM140YDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
RXTP25A / FTXTP25N
RXTP
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 4.95 | 4.95 | -30° | 2.50 | 2.50 | |
|
RXTP25A / FTXTP25A
RXTP
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 4.95 | 4.99 | -30° | 2.50 | 2.50 | |
|
MUZ-AY42VG/MSZ-AY42VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
MUZ-AY42VG2/MSZ-AY42VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
FDC100VNA-W/FDT50VH/FDT50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.41 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDT50VH/FDT50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.41 | 4.47 | 4.11 | -20° | 10.00 | 8.50 |