Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(5)
BRYANT
(0)
Buderus
(4)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(2)
Candy
(0)
DAIKIN
(2)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(8)
Fujitsu Atlantic
(0)
GENERAL
(8)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(14)
IVT
(0)
Inventor
(10)
KAYSUN
(0)
LG
(0)
MIDEA
(18)
MITSUBISHI ELECTRIC
(30)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(15)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(30)
THERMOR
(0)
TOSHIBA
(36)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GP801ATW-E/RAV-HM801CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 100 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 8.35 | 5.10 | 4.44 | -27° | 7.10 | 5.10 | |
|
RAV-GP801ATW-E/RAV-HM801UT-E
SDI
|
TOSHIBA | Cassette | 100 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 9.72 | 5.54 | 5.52 | -27° | 7.10 | 5.10 | |
|
RAV-GP801ATW-E/RAV-HM801UTP-E
SDI
|
TOSHIBA | Cassette | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 8.96 | 5.24 | 4.52 | -27° | 7.10 | 5.10 | |
|
RAV-GP801ATW-E/RAV-HM801BTP-E
SDI
|
TOSHIBA | Ducted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 7.86 | 4.85 | 4.32 | -27° | 7.10 | 5.10 | |
|
AOEH12KHCBN/ASEH12KHCBN
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
AOHH12KHCBN/ASHH12KHCBN
ASH**K
|
GENERAL | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
AOEH12KHCBN/ASEH12KHCBN-B
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
AOHH12KHCBN/ASHH12KHCBN-B
ASH**K
|
GENERAL | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
RAV-GP561ATW-E/RAV-HM561UT-E
SDI
|
TOSHIBA | Cassette | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 8.17 | 5.02 | 4.34 | -27° | 5.00 | 3.80 | |
|
AOEH14KHCBN/ASEH14KHCBN
ASE**K
|
FUJITSU | Wall mounted | 99 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.90 | 5.30 | 4.86 | -30° | 4.20 | 4.20 | |
|
AOHH14KHCBN/ASHH14KHCBN
ASH**K
|
GENERAL | Wall mounted | 99 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.90 | 5.30 | 4.86 | -30° | 4.20 | 4.20 | |
|
AOEH14KHCBN/ASEH14KHCBN-B
ASE**K
|
FUJITSU | Wall mounted | 99 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.90 | 5.30 | 4.86 | -30° | 4.20 | 4.20 | |
|
AOHH14KHCBN/ASHH14KHCBN-B
ASH**K
|
GENERAL | Wall mounted | 99 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.90 | 5.30 | 4.86 | -30° | 4.20 | 4.20 | |
|
RAS-35S4AVPG-ND/RAS-B35S4KVPG-ND
DSK10
|
TOSHIBA | Wall mounted | 99 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.40 | 5.06 | -30° | 3.50 | 3.80 | |
|
RAS-35S4AVPG-ND/RAS-B35S4KVDG-ND
DSK10
|
TOSHIBA | Wall mounted | 99 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.40 | 5.06 | -30° | 3.50 | 3.80 | |
|
MUZ-RZ35VUHZ/MSZ-RZ35VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.60 | 5.20 | 4.90 | -30° | 3.50 | 4.00 | |
|
RAV-GP561ATW-E/RAV-HM561UTP-E
SDI
|
TOSHIBA | Cassette | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.73 | 4.98 | 4.31 | -27° | 5.00 | 3.80 | |
|
RXTM40A / FTXTM40A
RXTM
|
DAIKIN | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.95 | 5.50 | 5.51 | -30° | 4.00 | 3.80 | |
|
RXTM40A / FTXTM40S
RXTM
|
DAIKIN | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.93 | 5.50 | 5.51 | -30° | 4.00 | 3.80 | |
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.90 | 4.38 | -25° | 5.00 | 4.10 | |
|
AC071BXAPKG/AC071BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.80 | 4.52 | -25° | 7.10 | 5.50 | |
|
AC071BXAPNG/AC071BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.80 | 4.52 | -25° | 7.10 | 5.50 | |
|
AC052BXAPKG/AC052BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.58 | -25° | 5.00 | 4.00 | |
|
RAV-GP1101AT-E/RAV-HM1101UT-E
SDI
|
TOSHIBA | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.03 | 5.14 | -27° | 10.00 | 9.20 | |
|
MUZ-RW35VGHZ / MSZ-RW35VG
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 4.90 | -30° | 3.50 | 4.00 | |
|
MUZ-RW35VGHZ2/MSZ-RW35VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 4.90 | -30° | 3.50 | 4.00 | |
|
RAV-GP1401AT-E1/RAV-HM1401UT-E
SDI
|
TOSHIBA | Cassette | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.87 | 5.00 | 4.61 | -27° | 12.50 | 9.60 | |
|
MUZ-LN35VGHZ2/MSZ-LN35VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 4.88 | -25° | 3.50 | 4.00 | |
|
MUZ-LN35VGHZ3/MSZ-LN35VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 4.88 | -25° | 3.50 | 4.00 | |
|
CU-HZ35ZKE / CS-HZ35ZKE
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.30 | 5.00 | -25° | 3.50 | 4.00 | |
|
CU-HZ35ZKE / CS-HZ35ZKE-H
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.30 | 5.00 | -25° | 3.50 | 4.00 | |
|
RAV-GP1101AT-E/RAV-HM1101UTP-E
SDI
|
TOSHIBA | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 4.76 | 4.79 | -27° | 10.00 | 9.20 | |
|
RAV-GP1101AT-E/RAV-HM1101FT-E
SDI
|
TOSHIBA | Floor standing | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.40 | 4.06 | -27° | 10.00 | 9.20 | |
|
AC052BXAPKG/AC052BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.30 | 4.60 | 3.70 | -25° | 5.00 | 3.90 | |
|
AC100BXAPKG/AC100BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.44 | -25° | 10.00 | 8.50 | |
|
AC100BXAPNG/AC100BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.44 | -25° | 10.00 | 8.50 | |
|
MUZ-FH35VEHZ/MSZ-FH35VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.90 | 4.80 | 5.00 | -25° | 3.50 | 4.00 | |
|
RAV-GP1401AT-E1/RAV-HM1401UTP-E
SDI
|
TOSHIBA | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 4.74 | 4.36 | -27° | 12.50 | 9.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401FT-E
SDI
|
TOSHIBA | Floor standing | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.49 | 4.38 | 3.00 | -27° | 12.30 | 9.60 | |
|
AC071BXAPKG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
AC071BXAPNG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
RAV-GP1101AT-E/RAV-HM1101CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.58 | 4.75 | 4.71 | -27° | 10.00 | 9.20 | |
|
AC071BXAPKG/AC071BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.08 | -25° | 7.10 | 5.00 | |
|
AC071BXAPNG/AC071BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.08 | -25° | 7.10 | 5.00 | |
|
CU-HZ35XKE / CS-HZ35XKE
2022
|
PANASONIC | Wall mounted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.30 | 5.00 | -25° | 3.50 | 4.00 | |
|
AC100BXAPKG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC100BXAPNG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC120BXAPNG / AC120BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 4.00 | -25° | 12.10 | 9.50 | |
|
RAV-GP1101AT-E/RAV-HM1101BTP-E
SDI
|
TOSHIBA | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.19 | 4.30 | 4.10 | -27° | 10.00 | 9.20 |