Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(8)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(5)
MIDEA
(0)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(19)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
FDC140VSX-W/FDT71VH/FDT71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 4.94 | 4.40 | 14.00 | 15.50 | ||
|
FDC140VSX-W/FDUM71VH/FDUM71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.21 | 4.68 | 4.10 | 14.00 | 15.50 | ||
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.25 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
FDC140VNX-W/FDUM71VH/FDUM71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.21 | 4.92 | 4.10 | 14.00 | 13.00 | ||
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
FDC140VNX-W/FDT71VH/FDT71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 5.07 | 4.40 | 14.00 | 13.00 | ||
|
FDC140VSX-W/FDE71VH/FDE71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.19 | 4.60 | 4.03 | 14.00 | 15.50 | ||
|
FDC140VNX-W/FDF71VH/FDF71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.76 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDF71VH1/FDF71VH1
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.76 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDE71VH/FDE71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.19 | 4.85 | 4.03 | 14.00 | 13.00 | ||
|
FDC200VSA/FDUM100VH/FDUM100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.77 | 3.71 | 19.00 | 12.50 | ||
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.92 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
FDC200VSA-W/FDUM100VH/FDUM100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.57 | 4.64 | 4.01 | 20.00 | 12.50 | ||
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
FDC200VSA-W/FDF100VH/FDF100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.73 | 3.70 | 20.00 | 12.50 | ||
|
FDC200VSA-W/FDF100VH1/FDF100VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.73 | 3.70 | 20.00 | 12.50 | ||
|
FDC200VSA/FDT100VH/FDT100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.37 | 4.58 | 3.72 | 19.00 | 12.50 | ||
|
FDC250VSA/FDUM125VH/FDUM125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.50 | 3.59 | 24.00 | 14.20 | ||
|
FDC200VSA-W/FDE100VH/FDE100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.53 | 3.96 | 20.00 | 12.50 | ||
|
FDC200VSA-W/FDT100VH/FDT100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.63 | 4.55 | 4.25 | 20.00 | 12.50 | ||
|
UUD1 U30 / UT60FH NA0
UU
|
LG | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.50 | 3.25 | 15.00 | 9.50 | ||
|
UUD3 U30 / UT60FH NA0
UU
|
LG | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.50 | 3.25 | 15.00 | 9.50 | ||
|
FDC200VSA/SRK100ZR-W/SRK100ZR-W
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.67 | 3.02 | 19.00 | 12.50 | ||
|
FM48AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM49AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 |