Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(23)
ATLANTIC
(25)
AUX
(8)
BOSCH
(71)
BRYANT
(0)
Buderus
(22)
CARRIER
(52)
CIAT
(8)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(5)
DAIKIN
(416)
EQUATION
(3)
FUJI ELECTRIC
(67)
FUJITSU
(152)
Fujitsu Atlantic
(79)
GENERAL
(118)
GREE
(68)
GSS
(0)
HAIER
(183)
HEC
(2)
HEIWA
(5)
HISENSE
(171)
HITACHI
(84)
IVT
(10)
Inventor
(46)
KAYSUN
(11)
LG
(133)
MIDEA
(239)
MITSUBISHI ELECTRIC
(348)
Mitsubishi Heavy Industries
(203)
NORD
(18)
Nobu
(0)
PANASONIC
(189)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(104)
THERMOR
(23)
TOSHIBA
(145)
Viessmann
(2)
Vulcano
(1)
WESTPOINT
(19)
YORK
(5)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM301ATP-E/RAV-HM301KRTP-E
DI
|
TOSHIBA | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.69 | 3.96 | 4.00 | -15° | 2.50 | 2.60 | |
|
SUZ-M25VA/SFZ-M25VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SFZ-M25VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
DJ25LE00W/DJ25LE00G
New Comfort
|
HISENSE | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 4.12 | -10° | 2.60 | 2.40 | |
|
DJ25LE0AW/DJ25LE00G
New Comfort
|
HISENSE | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 4.12 | -10° | 2.60 | 2.40 | |
|
RZASG71MV1 / FBA35A9 / FBA35A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.43 | 3.82 | 3.82 | -10° | 6.80 | 4.50 | |
|
FDC125VSX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.74 | 3.66 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VNX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.72 | 3.71 | 12.50 | 11.40 | ||
|
MOX133-09HFN8-QRD0GW/MSAGAU-09HRDN8-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
MA3-09HFN8-QRD0GW/MA3-09HRDN8-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
MOM-09N8D0-1/MAG2-07N8-1
Extreme save R32
|
MIDEA | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
MOM-09N8D0-1/MAG2-09N8-1
Extreme save R32
|
MIDEA | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
Ν2UVO-09/Ν2UVI-09WFI
Neo
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
N2VOCP-09/Ν2VICP-09WFI
Neo
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
VERO-09/VERI-09WFI
Vero
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
N3VO-09/N3VI-09WFI
Neo
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
MUY-TP35VF/MSY-TP35VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | — No score: too few class peers or too few declared metrics. Why? | 9.00 | 3.50 | |||||
|
MUY-TP35VF2/MSY-TP35VF2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | — No score: too few class peers or too few declared metrics. Why? | 9.00 | 3.50 | |||||
|
RAC-XJ25FHAE / RAF-XJ25RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.50 | 4.60 | 4.50 | -20° | 2.50 | 2.77 | |
|
RAC-XJ35FHAE / RAF-XJ35RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.20 | 4.61 | 3.90 | -20° | 3.50 | 3.02 | |
|
RAC-XJ50FHAE / RAF-XJ50RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 7.30 | 4.30 | 3.90 | -20° | 5.00 | 4.19 | |
|
U-200PZH4E8 / S-1014PU3E(2x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-6071PU3E(3x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PU3E(4x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 |