Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(16)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(37)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(12)
Fujitsu Atlantic
(9)
GENERAL
(9)
GREE
(4)
GSS
(0)
HAIER
(55)
HEC
(0)
HEIWA
(0)
HISENSE
(6)
HITACHI
(33)
IVT
(0)
Inventor
(19)
KAYSUN
(18)
LG
(9)
MIDEA
(96)
MITSUBISHI ELECTRIC
(45)
Mitsubishi Heavy Industries
(198)
NORD
(0)
Nobu
(0)
PANASONIC
(49)
RIELLO
(6)
Rotenso
(6)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(21)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(6)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC140VNA-W/FDT71VH/FDT71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.91 | 5.12 | 4.34 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDT71VH/FDT71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.91 | 5.12 | 4.34 | 13.60 | 10.50 | ||
|
FDC100VNX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
FDC140VNA/FDT71VH/FDT71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.51 | 4.89 | 4.17 | 13.60 | 10.50 | ||
|
FDC140VSA/FDT71VH/FDT71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.51 | 4.89 | 4.17 | 13.60 | 10.50 | ||
|
FDC200VSA-W/FDUM100VH/FDUM100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.57 | 4.64 | 4.01 | 20.00 | 12.50 | ||
|
FDC140VSX-W/FDF71VH/FDF71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.20 | 3.75 | 14.00 | 14.30 | ||
|
FDC140VSX-W/FDF71VH1/FDF71VH1
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.20 | 3.75 | 14.00 | 14.30 | ||
|
PUZ-ZM140VDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
FDC100VNX-W/SRK50ZSX-W/SRK50ZSX-W
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.66 | 4.25 | 4.31 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/SRK50ZSX-W/SRK50ZSX-W
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.66 | 4.25 | 4.31 | -20° | 10.00 | 11.20 | |
|
U-140PZH4E5 / S-1014PU3E
2023
|
PANASONIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.24 | 4.61 | 4.30 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
FDC140VNX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC140VSX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
PUZ-M200YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.35 | 3.60 | -20° | 19.00 | 15.50 | |
|
RAV-GP1101AT8-E/RAV-HM1101CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.23 | 4.46 | -20° | 10.00 | 11.60 | |
|
U-140PZH4E8 / S-1014PU3E
2023
|
PANASONIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.24 | 4.60 | 4.30 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.16 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.16 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
PUZ-ZM140VDA2/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC100VNX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
PUZ-ZM140YDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.49 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.49 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
FDC125VSX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.18 | 3.83 | 12.50 | 14.00 | ||
|
FDC125VSX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.94 | 4.36 | 2.91 | 12.50 | 14.00 | ||
|
FDC140VNA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
RZA200D
RZA
|
DAIKIN | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.20 | 19.00 | 11.20 | |||
|
U-250PZH4E8 / S-6071PF3E(4x)
2024
|
PANASONIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.00 | 3.75 | -20° | 21.50 | 17.20 | |
|
FDC140VSA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
AUF175UR4RHPA8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.80 | -10° | 16.00 | 10.00 | |
|
FDC200VSA-W/FDF100VH/FDF100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.73 | 3.70 | 20.00 | 12.50 | ||
|
FDC200VSA-W/FDF100VH1/FDF100VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.73 | 3.70 | 20.00 | 12.50 | ||
|
PUZ-ZM140VDA/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
RZA250D
RZA
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.33 | 22.00 | 12.10 | |||
|
FDC200VSA/FDT100VH/FDT100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.37 | 4.58 | 3.72 | 19.00 | 12.50 |