Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(3)
BRYANT
(0)
Buderus
(2)
CARRIER
(2)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(26)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(4)
Fujitsu Atlantic
(0)
GENERAL
(4)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(1)
MITSUBISHI ELECTRIC
(8)
Mitsubishi Heavy Industries
(10)
NORD
(0)
Nobu
(0)
PANASONIC
(2)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(4)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
COP up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-25S4AVPG-ND/RAS-B25S4KVPG-ND
DSK10
|
TOSHIBA | Wall mounted | 100 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.50 | 5.50 | 5.42 | -30° | 2.50 | 3.00 | |
|
RAS-25S4AVPG-ND/RAS-B25S4KVDG-ND
DSK10
|
TOSHIBA | Wall mounted | 100 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.50 | 5.50 | 5.42 | -30° | 2.50 | 3.00 | |
|
AOEH09KHCBN/ASEH09KHCBN
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.90 | 5.30 | 5.93 | -30° | 2.50 | 2.50 | |
|
AOHH09KHCBN/ASHH09KHCBN
ASH**K
|
GENERAL | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.90 | 5.30 | 5.93 | -30° | 2.50 | 2.50 | |
|
AOEH09KHCBN/ASEH09KHCBN
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.90 | 5.30 | 5.93 | -30° | 2.50 | 2.50 | |
|
AOHH09KHCBN/ASHH09KHCBN-B
ASH**K
|
GENERAL | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.90 | 5.30 | 5.93 | -30° | 2.50 | 2.50 | |
|
MUZ-RZ25VUHZ/MSZ-RZ25VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 11.70 | 5.30 | 5.50 | -30° | 2.50 | 3.20 | |
|
AOEH12KHCBN/ASEH12KHCBN
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
AOHH12KHCBN/ASHH12KHCBN
ASH**K
|
GENERAL | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
AOEH12KHCBN/ASEH12KHCBN-B
ASE**K
|
FUJITSU | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
AOHH12KHCBN/ASHH12KHCBN-B
ASH**K
|
GENERAL | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 10.60 | 5.30 | 5.41 | -30° | 3.50 | 3.60 | |
|
MUZ-RZ25VU/MSZ-RZ25VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.70 | 5.30 | 5.50 | -20° | 2.50 | 3.00 | |
|
RAS-10S4AVPG-E/RAS-B10S4KVPG-E
DSK10
|
TOSHIBA | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.70 | 5.30 | 5.33 | -20° | 2.50 | 3.00 | |
|
RAS-10S4AVPG-E/RAS-B10S4KVDG-E
DSK10
|
TOSHIBA | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.70 | 5.30 | 5.33 | -20° | 2.50 | 3.00 | |
|
MUZ-RW25VGHZ / MSZ-RW25VG
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 5.20 | 5.50 | -30° | 2.50 | 3.20 | |
|
MUZ-RW25VGHZ2/MSZ-RW25VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 5.20 | 5.50 | -30° | 2.50 | 3.20 | |
|
MUZ-LN25VGHZ2/MSZ-LN25VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.50 | 5.20 | 5.33 | -25° | 2.50 | 3.20 | |
|
MUZ-LN25VGHZ3/MSZ-LN25VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.50 | 5.20 | 5.33 | -25° | 2.50 | 3.20 | |
|
SRC25ZSX-W/SRK25ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.30 | 5.20 | 5.42 | -20° | 2.50 | 3.00 | |
|
MUZ-LN25VG2/MSZ-LN25VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.50 | 5.20 | 5.33 | -15° | 2.50 | 3.00 | |
|
MUZ-LN25VG3/MSZ-LN25VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.50 | 5.20 | 5.33 | -15° | 2.50 | 3.00 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 5.85 | 5.85 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 5.85 | 5.85 | 12.10 | 9.52 | ||
|
RZAG125NV1
RZAG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 13.20 | 5.29 | 5.29 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 13.20 | 5.29 | 5.29 | 12.10 | 9.52 | ||
|
RZASG140MV1
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 5.49 | 13.40 | 7.80 | ||
|
RZASG140MY1
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 5.49 | 13.40 | 7.80 | ||
|
RZASG140MV
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.60 | 5.49 | 13.40 | 7.80 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ceiling suspended | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 12.80 | 5.05 | 5.05 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Ceiling suspended | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 12.80 | 5.05 | 5.05 | 12.10 | 9.52 | ||
|
CU-VZ9SKE / CS-VZ9SKE
2016
|
PANASONIC | Wall mounted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.50 | 6.20 | 5.63 | -10° | 2.50 | 3.60 | |
|
CU-VZ12SKE / CS-VZ12SKE
2016
|
PANASONIC | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.90 | 5.06 | -10° | 3.50 | 4.20 | |
|
FDC125VNX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 5.10 | 3.10 | 12.50 | 11.40 | ||
|
RZAG140NV1
RZAG
|
DAIKIN | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.90 | 4.95 | 4.95 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.90 | 4.95 | 4.95 | 13.40 | 9.52 | ||
|
SRC25ZSX-W/SRK25ZSX-WF
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.30 | 5.20 | 5.42 | -10° | 2.50 | 3.00 | |
|
SRC25ZSX-W/SRK25ZSX-WFB
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.30 | 5.20 | 5.42 | -10° | 2.50 | 3.00 | |
|
SRC25ZSX-W/SRK25ZSX-WFT
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.30 | 5.20 | 5.42 | -10° | 2.50 | 3.00 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.40 | 4.87 | 4.87 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.40 | 4.87 | 4.87 | 13.40 | 9.52 | ||
|
RZAG125NV1
RZAG
|
DAIKIN | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 4.83 | 4.83 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 4.83 | 4.83 | 12.10 | 9.52 | ||
|
SRC20ZSX-W/SRK20ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.20 | 5.74 | -10° | 2.00 | 2.80 | |
|
SRC20ZSX-W/SRK20ZSX-WF
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.20 | 5.74 | -10° | 2.00 | 2.80 | |
|
SRC20ZSX-W/SRK20ZSX-WFB
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.20 | 5.74 | -10° | 2.00 | 2.80 | |
|
SRC20ZSX-W/SRK20ZSX-WFT
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.20 | 5.74 | -10° | 2.00 | 2.80 | |
|
FDC125VSX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 4.92 | 3.10 | 12.50 | 14.00 | ||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 |