Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(0)
AUX
(0)
BOSCH
(12)
BRYANT
(0)
Buderus
(6)
CARRIER
(5)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(67)
EQUATION
(0)
FUJI ELECTRIC
(5)
FUJITSU
(17)
Fujitsu Atlantic
(9)
GENERAL
(21)
GREE
(6)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(6)
IVT
(2)
Inventor
(5)
KAYSUN
(1)
LG
(12)
MIDEA
(17)
MITSUBISHI ELECTRIC
(24)
Mitsubishi Heavy Industries
(24)
NORD
(0)
Nobu
(0)
PANASONIC
(24)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(11)
THERMOR
(0)
TOSHIBA
(11)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RXM20A / FTXM20A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.00 | 2.30 | |
|
RXM20A / FTXM20A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.00 | 2.30 | |
|
AR70H09CAAWN/AR70H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR70H09CAABN/AR70H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
NH09SP2 U24A / NH09SP2 NS2
U24A
|
LG | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 5.42 | -10° | 2.50 | 3.80 | |
|
RXM25A / FTXM25A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.50 | 2.40 | |
|
AR70F09CAAWN/AR70F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR70F09CABWN/AR70F09CABWX
RAC
|
SAMSUNG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR50H09C1BHN/AR50H09C1BHX
RAC
|
SAMSUNG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
NH12SP2 U24A / NH12SP2 NS2
U24A
|
LG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 3.50 | 3.80 | |
|
F09MT U24 / F09MT NSM
U24A
|
LG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.40 | -10° | 2.50 | 3.70 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.72 | 4.43 | 12.10 | 9.52 | |||
|
F12MT U24 / F12MT NSM
U24A
|
LG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 5.10 | -10° | 3.50 | 3.80 | |
|
EXH-12RE1N-O/EX-12RE1N-I
Raynor
|
MIDEA | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.42 | -10° | 3.50 | 4.00 | |
|
MOX430-12HFN8-QRE1GW/MSEX1BU-12HRFN8-QRE1GW
Raynor
|
MIDEA | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.42 | -10° | 3.50 | 4.00 | |
|
RXM35A / FTXM35A
RXM
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.20 | 4.55 | -10° | 3.50 | 2.50 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.76 | 4.78 | 4.78 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.76 | 4.78 | 4.78 | 13.40 | 9.52 | ||
|
CU-2Z35CBE / CS-MZ16CKE / CS-Z20CKEW
2025
|
PANASONIC | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 4.80 | 5.06 | -15° | 3.50 | 3.20 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.41 | 4.40 | 13.40 | 9.52 | |||
|
AR70H12CAAWN/AR70H12CAAWX
RAC
|
SAMSUNG | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
AR70H12CAABN/AR70H12CAAWX
RAC
|
SAMSUNG | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
ARXM25A / ATXM25A
ARXM
|
DAIKIN | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.30 | 5.15 | 5.00 | -10° | 2.50 | 2.40 | |
|
SRC35ZSX-W/SRK35ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.78 | -10° | 3.50 | 3.40 | |
|
SRC35ZSX-W/SRK35ZSX-WF
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.78 | -10° | 3.50 | 3.40 | |
|
SRC35ZSX-W/SRK35ZSX-WFB
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.78 | -10° | 3.50 | 3.40 | |
|
SRC35ZSX-W/SRK35ZSX-WFT
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.78 | -10° | 3.50 | 3.40 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 4.64 | 4.64 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 4.64 | 4.64 | 13.40 | 9.52 | ||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 | ||
|
CL7000i 26 E / CL7000iU W 26 E
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
CL7000i 26 E / CL7000iU W 26 ES
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
CL7000i 26 E / CL7000iU W 26 EB
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
AC186i.3-2,6 / AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
AC186i.3-2,6 / AC186i.3-2,6 WB
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
MOX330-09HFN8-QRE1GWV/MSOPBU-09HRFN8-QRE1GWV
Oasis Plus
|
MIDEA | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
42QHP009E8S-2*/38QHP009E8S-2*
Wall mounted
|
CARRIER | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.10 | 4.71 | -10° | 2.60 | 2.20 | |
|
42QHP012E8S-2*/38QHP012E8S-2*
Wall mounted
|
CARRIER | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.00 | 5.10 | 4.71 | -10° | 3.50 | 2.20 | |
|
CL7000i 35 E / CL7000iU W 35 E
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
CL7000i 35 E / CL7000iU W 35 ES
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
CL7000i 35 E / CL7000iU W 35 EB
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
AC186i.3-3,5 / AC186i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
AC186i.3-3,5 / AC186i.3-3,5 WB
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 |