Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(4)
AUX
(6)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(11)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(152)
EQUATION
(0)
FUJI ELECTRIC
(20)
FUJITSU
(63)
Fujitsu Atlantic
(22)
GENERAL
(15)
GREE
(1)
GSS
(0)
HAIER
(62)
HEC
(0)
HEIWA
(0)
HISENSE
(9)
HITACHI
(21)
IVT
(0)
Inventor
(20)
KAYSUN
(1)
LG
(25)
MIDEA
(16)
MITSUBISHI ELECTRIC
(97)
Mitsubishi Heavy Industries
(131)
NORD
(0)
Nobu
(0)
PANASONIC
(21)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(18)
THERMOR
(0)
TOSHIBA
(53)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC100VNA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
RXTM30A / FVXTM30B
RXTM
|
DAIKIN | Floor standing | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.75 | 4.44 | -30° | 3.00 | 3.00 | |
|
RZASG71MV1 / FHA35A9 / FHA35A9
RZASG
|
DAIKIN | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.38 | 4.38 | -10° | 6.80 | 4.50 | |
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
PUZ-ZM125VDA/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
FDC140VNA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
RAV-GM1102ATW-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.91 | -15° | 9.50 | 8.00 | |
|
RXM35A9 / FVXM35B
RXM
|
DAIKIN | Floor standing | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.19 | 4.68 | 3.91 | -20° | 3.40 | 2.80 | |
|
AC35S2SG2FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.47 | 3.73 | -10° | 3.50 | 3.00 | |
|
FDC140VSA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
AUF175UR4RHPA8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.80 | -10° | 16.00 | 10.00 | |
|
FDC200VSA-W/FDF100VH/FDF100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.73 | 3.70 | 20.00 | 12.50 | ||
|
FDC200VSA-W/FDF100VH1/FDF100VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.73 | 3.70 | 20.00 | 12.50 | ||
|
RZAG71NV1 / FHA71A9
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.32 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FHA71A9
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.32 | -10° | 6.80 | 4.70 | ||
|
PUZ-ZM140VDA/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM125YDA/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
RZAG100NV1 / FHA100A
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.61 | 3.97 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FHA100A
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.61 | -10° | 9.50 | 7.80 | ||
|
RAC-50FXE / RAF-50RXE
RAC-FXE
|
HITACHI | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.80 | -20° | 5.00 | 4.61 | |
|
PUZ-ZM100VDA/PCA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.30 | 3.60 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PCA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.30 | 3.60 | -20° | 9.50 | 7.80 | |
|
RAV-GP1101AT8-E/RAV-HM1101FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.14 | 4.02 | 4.04 | -20° | 10.00 | 10.80 | |
|
PUZ-ZM140YDA/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.31 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.31 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
RZAG50A / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -20° | 5.00 | 4.00 | |
|
U-140PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.64 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
FDC71VNX-W/FDE71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.58 | 4.45 | 4.28 | -20° | 7.10 | 6.00 | |
|
RAV-GP1401AT8-E1/RAV-HM1401CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.21 | 4.02 | -20° | 12.50 | 11.80 | |
|
UUC1 U40 / UV30F N10
U4
|
LG | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 3.44 | -10° | 7.70 | 5.40 | |
|
RZAG100NV1 / FUA100A
RZAG
|
DAIKIN | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.50 | 4.03 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FUA100A
RZAG
|
DAIKIN | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.50 | -10° | 9.50 | 7.80 | ||
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
FDC100VNA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
AUW105U4RW8/AUV105UR4RC8
Turbo Inverter R32
|
HISENSE | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.73 | -10° | 9.50 | 8.00 | |
|
AUW105U6RW8/AUV105UR4RC8
Turbo Inverter R32
|
HISENSE | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.73 | -10° | 9.50 | 8.00 | |
|
UUD1 U30 / UV36FH N20
UU
|
LG | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 4.25 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UV36FH N20
UU
|
LG | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 4.25 | -10° | 9.50 | 9.50 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 |