Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(4)
AUX
(6)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(10)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(112)
EQUATION
(0)
FUJI ELECTRIC
(17)
FUJITSU
(54)
Fujitsu Atlantic
(19)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(51)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(14)
IVT
(0)
Inventor
(8)
KAYSUN
(0)
LG
(22)
MIDEA
(0)
MITSUBISHI ELECTRIC
(43)
Mitsubishi Heavy Industries
(64)
NORD
(0)
Nobu
(0)
PANASONIC
(21)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(11)
THERMOR
(0)
TOSHIBA
(29)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC100VNA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
AUW105U4RW8/AUV105UR4RC8
Turbo Inverter R32
|
HISENSE | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.73 | -10° | 9.50 | 8.00 | |
|
AUW105U6RW8/AUV105UR4RC8
Turbo Inverter R32
|
HISENSE | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.73 | -10° | 9.50 | 8.00 | |
|
UUD1 U30 / UV36FH N20
UU
|
LG | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 4.25 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UV36FH N20
UU
|
LG | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 4.25 | -10° | 9.50 | 9.50 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
PUZ-ZM71VHA2/PCA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.71 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.71 | -20° | 7.10 | 4.70 | |
|
FDC71VNX-W/FDE40VH/FDE40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.48 | 4.49 | 3.81 | -20° | 7.10 | 6.00 | |
|
FDC200VSA-W/FDE100VH/FDE100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.53 | 3.96 | 20.00 | 12.50 | ||
|
U-36PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.61 | -15° | 3.50 | 2.80 | |
|
RAV-GM1102AT8W-E/RAV-HM1101CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.46 | 4.29 | 3.95 | -15° | 9.50 | 8.00 | |
|
SRC35ZS-W2/SRR35ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.50 | 4.16 | -10° | 3.50 | 3.10 | |
|
RZAG60A / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -20° | 6.00 | 4.60 | |
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
UUD1 U30 / UV42FH N20
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.60 | 12.10 | 9.50 | ||
|
UUD3 U30 / UV42FH N20
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.60 | 12.10 | 9.50 | ||
|
UUA1 UL0 / UV18F N10
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 3.70 | -10° | 5.00 | 2.90 | |
|
PUZ-ZM100YDA/PCA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.30 | 3.60 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PCA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.30 | 3.60 | -20° | 9.50 | 7.80 | |
|
RAV-GM401ATP-E/RAV-HM401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.34 | 5.10 | 5.13 | -15° | 3.60 | 2.70 | |
|
RAS-2.5HVRC3 / RPC-2.5FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.05 | 3.72 | -25° | 5.60 | 5.20 | |
|
RZAG71NV1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
U-100PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 4.24 | -15° | 10.00 | 10.00 | |
|
FDC100VNP-W/FDE100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.63 | 4.24 | 4.24 | -15° | 10.00 | 6.00 | |
|
U-100PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 4.24 | -15° | 10.00 | 10.00 | |
|
RZAG140NV1 / FHA140A
RZAG
|
DAIKIN | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.30 | 13.40 | 9.52 | |||
|
RZAG140NY1 / FHA140A
RZAG
|
DAIKIN | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.30 | 13.40 | 9.52 | |||
|
RZAG125NV1 / FHA125A
RZAG
|
DAIKIN | Ceiling suspended | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.20 | 12.10 | 9.52 | |||
|
FDC125VNX-W/FDE125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.20 | 2.90 | 12.50 | 11.40 | ||
|
RAV-GM901ATP-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
RZAG50B / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -10° | 5.00 | 4.00 | |
|
RZAG125NV1 / FUA125A
RZAG
|
DAIKIN | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.26 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FUA125A
RZAG
|
DAIKIN | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.26 | 12.10 | 9.52 | |||
|
FDC250VSA-W/FDE125VH/FDE125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.25 | 3.53 | 25.00 | 14.20 | ||
|
RZAG125NY1 / FHA125A
RZAG
|
DAIKIN | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.20 | 12.10 | 9.52 | |||
|
AUW60U4RJ7/AVT60UR4RB8
Super Inverter R32
|
HISENSE | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.80 | -10° | 6.20 | 5.50 | |
|
AOYG36KBTB/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KBTB/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KBTB/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KBTB/ABEG36KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KBTB/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 |