Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(4)
AUX
(6)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(10)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(112)
EQUATION
(0)
FUJI ELECTRIC
(17)
FUJITSU
(54)
Fujitsu Atlantic
(19)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(51)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(14)
IVT
(0)
Inventor
(8)
KAYSUN
(0)
LG
(22)
MIDEA
(0)
MITSUBISHI ELECTRIC
(43)
Mitsubishi Heavy Industries
(64)
NORD
(0)
Nobu
(0)
PANASONIC
(21)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(11)
THERMOR
(0)
TOSHIBA
(29)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
RXM60R / FHA60A9
RXM
|
DAIKIN | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.08 | 3.87 | 3.32 | -15° | 5.70 | 4.71 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
AC140S2SK1FA/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
AC140S2SK1FA(H)/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
PUZ-M140YKA2/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA2/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA3/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA3/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
U-125PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
AC125S2SK1FA/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC125S2SK1FA(H)/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC125S2SK2FA(H)/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC 048 DB.UI/1U 048 DC.UE
R32 Super Match Plus - Convertible
|
ATLANTIC | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.21 | 12.40 | 8.00 | ||
|
FDC280VSA-W/FDE140VH/FDE140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.95 | 3.34 | 27.00 | 16.00 | ||
|
U-125PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
AC125S2SK1FA/1U125S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.97 | 3.21 | 12.30 | 8.00 | ||
|
AC125S2SK1FA(H)/1U125S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.97 | 3.21 | 12.30 | 8.00 | ||
|
AC125S2SK2FA(H)/1U125S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.97 | 3.21 | 12.30 | 8.00 | ||
|
AC140S2SK1FA/1U140S2SP1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.70 | 13.40 | 11.00 | ||
|
RZASG71MV1 / FUA71A
RZASG
|
DAIKIN | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 3.90 | 3.89 | -10° | 6.80 | 4.50 | |
|
AOYG30KATA/ABYG30KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
ROG30KATA/RYG30KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ABEG30KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ABYG30KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
FDC100VNX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
PUZ-ZM71VHA2/PCA-M71HA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71HA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
FDC100VSX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
AC105S2SH1FA/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC105S2SH2FA(H)/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC 024 DB.UI/1U 024 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.26 | -10° | 7.10 | 5.00 | |
|
AOYG54KRTA/ABYG54KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
AOHG54KRTA/ABHG54KRTA
ABY**K
|
GENERAL | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
ROG54KRTA/RYG54KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
AOEG54KRTA/ABEG54KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
AOEG54KRTA/ABYG54KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
AOYG54KRTA/ABYG54KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
RZASG100MV1 / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | 4.81 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | 4.81 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FHA100A
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.91 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | -10° | 9.50 | 6.00 |