Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(0)
AUX
(0)
BOSCH
(4)
BRYANT
(0)
Buderus
(3)
CARRIER
(2)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(57)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(4)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(8)
MITSUBISHI ELECTRIC
(16)
Mitsubishi Heavy Industries
(30)
NORD
(0)
Nobu
(0)
PANASONIC
(2)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(2)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
FDC125VNX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.80 | 3.10 | 12.50 | 11.40 | ||
|
FDC140VSX-W/FDUM71VH/FDUM71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.21 | 4.68 | 4.10 | 14.00 | 15.50 | ||
|
FDC140VNX-W/FDUM71VH/FDUM71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.21 | 4.92 | 4.10 | 14.00 | 13.00 | ||
|
RZAG100NV1 / FNA50A9 / FNA50A9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FNA50A9 / FNA50A9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FDXM50F9 / FDXM50F9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
RZAG100NV1 / FDXM50F9 / FDXM50F9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
FDC125VSX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.60 | 2.90 | 12.50 | 14.00 | ||
|
FDC140VNA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC140VSA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDUM71VH/FDUM71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.22 | 3.69 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDUM71VH/FDUM71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.22 | 3.69 | 13.60 | 10.50 | ||
|
FDC125VNA-W/FDUM60VH/FDUM60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.78 | 3.98 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDUM60VH/FDUM60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.78 | 3.98 | 12.50 | 9.80 | ||
|
FDC200VSA/FDUM100VH/FDUM100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.77 | 3.71 | 19.00 | 12.50 | ||
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.34 | 4.51 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.34 | 4.51 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.34 | 4.51 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.34 | 4.51 | 13.40 | 7.80 | |||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 4.31 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 4.31 | 12.10 | 9.52 | |||
|
FDC200VSA-W/FDUM100VH/FDUM100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.57 | 4.64 | 4.01 | 20.00 | 12.50 | ||
|
FDC140VNX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC140VSX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC125VNA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
M2OF-18HFN8-Q/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
FDC125VSX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.18 | 3.83 | 12.50 | 14.00 | ||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.18 | 4.18 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.18 | 4.18 | 13.40 | 9.52 | ||
|
FDC125VNX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.21 | 4.26 | 3.83 | 12.50 | 11.40 | ||
|
FDC250VSA-W/FDUM125VH/FDUM125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.40 | 3.54 | 25.00 | 14.20 | ||
|
FDC250VSA/FDUM125VH/FDUM125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.50 | 3.59 | 24.00 | 14.20 | ||
|
RZASG71MV1 / FDXM35F9 / FDXM35F9
RZASG
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.22 | 4.22 | -10° | 6.80 | 4.50 | |
|
RZASG71MV1 / FNA35A9 / FNA35A9
RZASG
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.22 | 4.22 | -10° | 6.80 | 4.50 | |
|
RZA250D
RZA
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.10 | 22.00 | 12.10 | |||
|
RZA200D
RZA
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.32 | 4.10 | 19.00 | 11.20 | |||
|
RZAG71NV1 / FNA35A9 / FNA35A9
RZAG
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.14 | 4.14 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FNA35A9 / FNA35A9
RZAG
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.14 | 4.14 | -10° | 6.80 | 4.70 | |
|
PUZ-ZM100VDA/PEAD-M50JA2/PEAD-M50JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PEAD-M50JAL2/PEAD-M50JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PEAD-M50JA3/PEAD-M50JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PEAD-M50JAL3/PEAD-M50JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 |