Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(9)
ATLANTIC
(0)
AUX
(4)
BOSCH
(6)
BRYANT
(0)
Buderus
(1)
CARRIER
(3)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(40)
EQUATION
(0)
FUJI ELECTRIC
(3)
FUJITSU
(9)
Fujitsu Atlantic
(3)
GENERAL
(3)
GREE
(1)
GSS
(0)
HAIER
(22)
HEC
(0)
HEIWA
(0)
HISENSE
(10)
HITACHI
(7)
IVT
(2)
Inventor
(15)
KAYSUN
(4)
LG
(6)
MIDEA
(39)
MITSUBISHI ELECTRIC
(54)
Mitsubishi Heavy Industries
(67)
NORD
(3)
Nobu
(0)
PANASONIC
(8)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(7)
THERMOR
(3)
TOSHIBA
(24)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOX630U-48HFN8-RRD0W(GA)/MFFN-55HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.41 | -10° | 14.10 | 11.30 | |
|
FDC125VSX-W/FDF125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.85 | 3.61 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDF125VH1
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.85 | 3.61 | 12.50 | 14.00 | ||
|
AP140S2SK1FA/1U140S2SN1FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 3.95 | 2.76 | 13.40 | 8.50 | ||
|
AP140S2SK1FA(H)/1U140S2SN1FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 3.95 | 2.76 | 13.40 | 8.50 | ||
|
SUZ-M71VA/PSA-M71KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PSA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.21 | -10° | 7.10 | 5.80 | |
|
MOX630U-55HFN8-RRD0W(GA)/MFFN-55HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.00 | -10° | 15.80 | 12.20 | |
|
RZA200D
RZA
|
DAIKIN | Floor standing | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.06 | 3.90 | 19.00 | 11.20 | |||
|
AW-YXDL012-H91/AW-XDL012-N91
XDL
|
AIRWELL | Console | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.96 | -10° | 3.50 | 3.20 | |
|
YDAF-035R-09M25/XDLF-035N-09M25
XDLF
|
AIRWELL | Console | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.96 | -10° | 3.50 | 3.20 | |
|
AF25S2SD1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
AF25S2SD1FA(D)/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
NAGANO CONSOLE IC26V3-NG / E1U26LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
SUZ-M60VA/MFZ-KT60VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.21 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/MFZ-KT60VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.21 | -10° | 6.10 | 4.60 | |
|
AP140S2SE1FA(H)/1U140S2SN1FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 3.95 | 2.76 | 13.40 | 8.50 | ||
|
RZA250D
RZA
|
DAIKIN | Floor standing | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 3.90 | 22.00 | 12.10 | |||
|
PUZ-ZM125VDA/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.40 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.40 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.37 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.37 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
V6FO-60/V6FI-60
Floor Standing
|
Inventor | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.70 | 3.75 | -10° | 14.00 | 10.79 | |
|
AOYG14KVCA/AGYG14KVCA
AGY**K
|
FUJITSU | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOHG14KVCA/AGHG14KVCA
AGH**K
|
GENERAL | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
ROG14KVCA/RGG14KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOEG14KVCA/AGEG14KVCA
AGE**K
|
FUJITSU | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOEG14KVCA/AGYG14KVCA
AGY**K
|
FUJITSU | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOYG14KVCA/AGYG14KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AC035BXAPKG/AC035BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.13 | -25° | 3.50 | 2.00 | |
|
SUZ-M25VA2/MFZ-KT25VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.71 | -10° | 2.50 | 2.20 | |
|
AUW52U4RS7/AKT52UR4RK8
Super Inverter R32
|
HISENSE | Console | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.50 | -10° | 4.90 | 3.50 | |
|
FDC125VNA/FDF125VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.96 | 3.38 | 12.50 | 9.80 | ||
|
AF50S2SD1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.24 | -10° | 5.00 | 3.40 | |
|
SUZ-M71VA/SFZ-M71VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/SFZ-M71VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.80 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
FDC125VNA-W/FDF125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.35 | 3.96 | 3.42 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDF125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.35 | 3.96 | 3.42 | 12.50 | 9.80 | ||
|
FDC125VNA-W/FDF125VH1
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.35 | 3.96 | 3.42 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDF125VH1
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.35 | 3.96 | 3.42 | 12.50 | 9.80 | ||
|
FDC140VNA-W/FDF140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.99 | 3.11 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDF140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.99 | 3.11 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDF140VH1
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.99 | 3.11 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDF140VH1
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.99 | 3.11 | 13.60 | 10.50 | ||
|
FDC125VSA/FDF125VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.96 | 3.38 | 12.50 | 9.80 | ||
|
FDC280VSA-W/FDF140VH/FDF140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 4.13 | 3.17 | 27.00 | 17.80 | ||
|
FDC280VSA-W/FDF140VH1/FDF140VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 4.13 | 3.17 | 27.00 | 17.80 | ||
|
AP140S2SK1FA/1U140S2SN1FA
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.93 | 2.75 | 13.40 | 8.50 | ||
|
AP140S2SK1FA(H)/1U140S2SN1FA
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.93 | 2.75 | 13.40 | 8.50 |