Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(3)
FUJITSU
(5)
Fujitsu Atlantic
(4)
GENERAL
(4)
GREE
(0)
GSS
(0)
HAIER
(10)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(4)
IVT
(0)
Inventor
(1)
KAYSUN
(0)
LG
(7)
MIDEA
(0)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(60)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
FDC140VSA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
FDC140VNA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
FDC140VNA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC140VSA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC200VSA/FDUM100VH/FDUM100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.77 | 3.71 | 19.00 | 12.50 | ||
|
FDC140VNX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC140VSX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC125VNA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
FDC125VSX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.18 | 3.83 | 12.50 | 14.00 | ||
|
FDC125VNX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.21 | 4.26 | 3.83 | 12.50 | 11.40 | ||
|
FDC250VSA/FDUM125VH/FDUM125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.50 | 3.59 | 24.00 | 14.20 | ||
|
FDC140VSX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.15 | 3.22 | 14.00 | 14.30 | ||
|
FDC140VNX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.15 | 3.22 | 14.00 | 13.00 | ||
|
FDC100VNA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 | |
|
FDC100VNA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC250VSA/FDF125VD/FDF125VD
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.45 | 4.25 | 3.18 | 24.00 | 14.20 | ||
|
FDC100VNX/FDU100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VNX/FDUM100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VSX/FDU100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.19 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VSX/FDUM100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.19 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC140VNA/FDF140VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.10 | 4.17 | 3.11 | 13.00 | 10.50 | ||
|
FDC125VNA/FDU125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA/FDU125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC140VSA/FDF140VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.03 | 4.17 | 3.11 | 13.60 | 10.50 | ||
|
FDC125VNA/FDUM125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
AOYG36LATT/ARYG36LMLA
ARY**L
|
FUJITSU | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.90 | -15° | 10.00 | 10.00 | |
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOHG90LRLA/ARHG90LHTA
AOHG**L
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
ROG90LRLA/RDG90LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
RPIL-1.5UNE1NH / RAS-1.5UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.82 | -15° | 3.52 | 3.52 | |
|
ADH140H1ERG/1UH140P1ERG
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 14.00 | 11.00 | ||
|
ADH140H1ERG/1UH140P1ERK
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 14.00 | 11.00 | ||
|
AD140S2SM3FA/1UH140P1ERG
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.43 | 13.40 | 10.00 | ||
|
AD140S2SM3FA/1UH140P1ERK
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.43 | 13.40 | 10.00 | ||
|
FDC140VNA/FDU140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.08 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA/FDUM140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.08 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
ADH125H1ERG/1UH125P1ERG
Smart Power - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 12.50 | 10.00 |