Filters
Manufacturer:
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FM56AH.U34 [EAU609054**]
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 14.70 | 9.50 | ||
|
FM57AH.U34/CT18F.NQ0/CT18F.NQ0/CT18F.NQ0 [EAU609054**]
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 14.70 | 9.50 | ||
|
A9UW56GFA1 [EAU609054**]
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 14.70 | 9.50 | ||
|
AR50F12C1BHN/AR50F12C1BHX
RAC
|
SAMSUNG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.61 | -11° | 3.50 | 2.30 | |
|
FDC140VNX/FDUM140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.85 | 3.62 | 14.00 | 13.00 | ||
|
RZASG100MV1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | -10° | 9.50 | 6.00 | ||
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
ROG09KATA/RDG09KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOHG09KATA/ARXG09KLLAP
ARXG**K
|
GENERAL | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOEG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AW-YXDL018-H91/AW-XDL018-N91
XDL
|
AIRWELL | Console | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.55 | -10° | 5.20 | 5.00 | |
|
YDAF-050R-09M25/XDLF-050N-09M25
XDLF
|
AIRWELL | Console | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.55 | -10° | 5.20 | 5.00 | |
|
PUZ-M125VKA2/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.29 | 3.85 | 3.10 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.29 | 3.85 | 3.10 | -15° | 12.10 | 8.50 | |
|
UUC1 U40 / UM30F NA0
U4
|
LG | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.71 | -10° | 7.50 | 5.40 | |
|
AZAS140MV / FBA140A
AZAS
|
DAIKIN | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.85 | 13.40 | 7.80 | |||
|
AZAS140MY / FBA140A
AZAS
|
DAIKIN | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.85 | 13.40 | 7.80 | |||
|
M2OH-14HFN8-Q/MSGPAU-09HRFN8-QRD6GW+MSGPAU-09HRFN8-QRD6GW
M2OH-14HFN8-Q
|
MIDEA | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 4.10 | -10° | 4.10 | 3.80 | |
|
M2OH-14HFN8-Q(H)/EZ-09RD6-I+EZ-09RD6-I
M2OH-14HFN8-Q
|
MIDEA | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 4.10 | -10° | 4.10 | 3.80 | |
|
ZDAA-2040-09M25/HDMC-025N-09M25x2
ZDAA
|
AIRWELL | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 4.10 | -10° | 4.10 | 3.80 | |
|
ADH125H1ERG/1U125S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.70 | 3.42 | 12.10 | 8.00 | ||
|
ADH125H1ERG/1U125S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.70 | 3.42 | 12.10 | 8.00 | ||
|
RAV-GM402ATP-E/RAV-HM401U1TP-E
DI
|
TOSHIBA | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.03 | -15° | 3.60 | 2.70 | |
|
W18TI UEU / W18TI NEU
18TI
|
LG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -15° | 5.10 | 3.80 | |
|
ABH160K1ERG/1U160S2SP1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.96 | 3.99 | 3.04 | 15.00 | 11.00 | ||
|
ABH160K1ERG(H)/1U160S2SP1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.96 | 3.99 | 3.04 | 15.00 | 11.00 | ||
|
AB160S2SR1FA(H)/1U160S2SP1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.96 | 3.99 | 3.04 | 15.00 | 11.00 | ||
|
AC105S2SH1FA(H)/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.50 | -10° | 9.50 | 6.00 | |
|
AB125S2SR1FA(H)/1U125S2SN3FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.93 | 3.50 | 12.50 | 8.30 | ||
|
AB125S2SR1FA(H)/1U125S2SN3FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.93 | 3.50 | 12.50 | 8.30 | ||
|
AD50S2SS1FA(H)/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.73 | -10° | 5.00 | 4.30 | |
|
PUZ-M200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.48 | 3.61 | 3.40 | -20° | 19.00 | 15.50 | |
|
PUZ-M125YKA3/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.29 | 3.84 | 3.10 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.29 | 3.84 | 3.10 | -15° | 12.10 | 8.50 | |
|
AD50S2SM3FA/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.00 | 4.50 | |
|
MU5R40 U42 / MJ18PC NSK / MJ24PC NSK
MU
|
LG | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.05 | -15° | 10.00 | 8.00 | |
|
RAS-18B2AVG-E2/RAS-B18B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18B2AVG-E2/RAS-B18B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18LAV2G-E/RAS-B18LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
38WHSS050ATA0TEE/40WHSW050DTA0TEE
40WHS
|
CARRIER | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RZAG35B / FFA35A9
RZAG
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -10° | 3.50 | 4.20 | |
|
PUZ-ZM35VKA2/PKA-M35LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/PKA-M35LAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PKA-M35LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PKA-M35LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
ABH140K1ERG/1UH140P1ERK
Smart Power - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 13.50 | 10.00 |