Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(18)
ATLANTIC
(22)
AUX
(4)
BOSCH
(54)
BRYANT
(0)
Buderus
(20)
CARRIER
(30)
CIAT
(4)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(2)
DAIKIN
(135)
EQUATION
(2)
FUJI ELECTRIC
(11)
FUJITSU
(37)
Fujitsu Atlantic
(18)
GENERAL
(38)
GREE
(31)
GSS
(0)
HAIER
(138)
HEC
(0)
HEIWA
(4)
HISENSE
(82)
HITACHI
(23)
IVT
(9)
Inventor
(40)
KAYSUN
(6)
LG
(26)
MIDEA
(194)
MITSUBISHI ELECTRIC
(57)
Mitsubishi Heavy Industries
(34)
NORD
(16)
Nobu
(0)
PANASONIC
(55)
RIELLO
(4)
Rotenso
(0)
SAMSUNG
(35)
THERMOR
(15)
TOSHIBA
(44)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(19)
YORK
(1)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AS 007 JDB.UI/1U 007 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.75 | 4.20 | 4.80 | -10° | 2.40 | 2.50 | |
|
GWH12YCXD-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.40 | 4.00 | -10° | 3.50 | 3.20 | |
|
GWH12YCXD-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.40 | 4.00 | -10° | 3.50 | 3.20 | |
|
AS35XCHHRA-NR/1U35KEHFRA-NR
Wall mounted - EXPERT Nordic
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.20 | -10° | 3.50 | 3.60 | |
|
AS25XCHHRA-NR/1U25KEHFRA-NR
Wall mounted - EXPERT Nordic
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 4.20 | -10° | 2.60 | 3.00 | |
|
AS25PBPHRA-PRE/1U25YEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
AS25PBPHRA-PRE/1U25YEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
UI 2,7 kW MURAO SMART BLANC & UE MONO 2,7 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
CL5000i 35 E / CL5000iU W 35 E
Climate 5000i
|
BOSCH | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.30 | 3.93 | -10° | 3.30 | 2.60 | |
|
AS71PEPHRA-PRE/1U71WEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.00 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71PEPHRA-PRE/1U71WEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.00 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS 007 NBB.UI/1U 007 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.00 | -10° | 2.10 | 1.90 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
WIM-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
AS35PBPHRA-PRE/1U35MEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 3.30 | 2.80 | |
|
AS35S2SF1FA-MW3/1U35MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
AS 012 NBB.UI/1U 012 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
AS35PBPHRA-PRE/1U35MEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 3.30 | 2.80 | |
|
AS35S2SF1FA-MB3/1U35MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
AS35S2SF1FA-S/1U35S2SM1FA-2
Super Match mono Flexis-Silver
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
UI 3,6 kW MURAO SMART BLANC & UE MONO 3,6 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 3.30 | 2.80 | |
|
GWH12AGCXB-K6DNA1G
MONOSPLITS
|
GREE | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.10 | 3.80 | -10° | 3.20 | 2.80 | |
|
GWH12AGCXB-K6DNA2G
MONOSPLITS
|
GREE | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.10 | 3.80 | -10° | 3.20 | 2.80 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
UI 5,3 kW MURAO SMART BLANC & UE MONO 5,3 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS25S2SF1FA-MW3/1U25MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
AS 009 NBB.UI/1U 009 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
AS25S2SF1FA-MB3/1U25MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
AS25S2SF1FA-S/1U25S2SM1FA-2
Super Match mono Flexis-Silver
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
Virtus-9K-IN/Virtus-9K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
Virtus-12K-IN/Virtus-12K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 3.81 | -10° | 3.50 | 2.80 | |
|
MUY-TP35VF/MSY-TP35VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | — No score: too few class peers or too few declared metrics. Why? | 9.00 | 3.50 | |||||
|
MUY-TP35VF2/MSY-TP35VF2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | — No score: too few class peers or too few declared metrics. Why? | 9.00 | 3.50 | |||||
|
RAC-XJ25FHAE / RAF-XJ25RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.50 | 4.60 | 4.50 | -20° | 2.50 | 2.77 |