Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(4)
BRYANT
(0)
Buderus
(4)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(2)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(5)
MITSUBISHI ELECTRIC
(5)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-RZ25VUHZ/MSZ-RZ25VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 11.70 | 5.30 | 5.50 | -30° | 2.50 | 3.20 | |
|
MUZ-RZ25VU/MSZ-RZ25VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.70 | 5.30 | 5.50 | -20° | 2.50 | 3.00 | |
|
MUZ-RZ35VUHZ/MSZ-RZ35VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.60 | 5.20 | 4.90 | -30° | 3.50 | 4.00 | |
|
MUZ-RZ35VU/MSZ-RZ35VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.60 | 5.20 | 4.90 | -20° | 3.50 | 3.60 | |
|
MUZ-RZ50VUHZ/MSZ-RZ50VU
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -30° | 5.00 | 6.00 | |
|
MOX331-09HFN7-QRD6GW/MSAGBU-09HRFN7-QRD6GW(A)
Extreme save R290
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
MOX331-09HFN7-QRD6GW/MSAGBU-09HRFN7-QRD6GW(B)
Extreme save R290
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL6000iP 26 / CL6000iP W 26 F
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC176iP-2,6 / AC176iP-2,6 W
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL6000iP 26 / CL6000iP W 26
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC176iP-2,6 / AC176iP-2,6 W S
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
GWH09ATCXB-K5DNA1B
MONOSPLITS
|
GREE | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.40 | -10° | 2.70 | 2.70 | |
|
AG-12RD6N7H-O/AG-12RD6N7-I
Extreme save R290
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
MOX331-12HFN7-QRD6GW/MSAGBU-12HRFN7-QRD6GW(A)
Extreme save R290
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
MOX331-12HFN7-QRD6GW/MSAGBU-12HRFN7-QRD6GW(B)
Extreme save R290
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35 F
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
AC176iP-3,5 / AC176iP-3,5 W
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
AC176iP-3,5 / AC176iP-3,5 W S
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
GWH12ATCXB-K5DNA1B
MONOSPLITS
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 4.20 | -10° | 3.20 | 2.80 |