Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(3)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(20)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(1)
MIDEA
(0)
MITSUBISHI ELECTRIC
(41)
Mitsubishi Heavy Industries
(40)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(5)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-FH35VEHZ/MSZ-FH35VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.90 | 4.80 | 5.00 | -25° | 3.50 | 4.00 | |
|
MUZ-FH35VE/MSZ-FH35VE2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.90 | 5.10 | 5.00 | -15° | 3.50 | 3.60 | |
|
RAS-4HVNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.44 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HVNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
MUZ-FH25VEHZ/MSZ-FH25VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 4.90 | 5.52 | -25° | 2.50 | 3.20 | |
|
RAS-4HNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.43 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.52 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
MUZ-FH25VE/MSZ-FH25VE2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 5.52 | -15° | 2.50 | 3.00 | |
|
FDC100VNA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.26 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDT50VH/FDT50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.89 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT50VH/FDT50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.89 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
RAS-4HVNC2E / RCI-4.0FS1R
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.40 | 4.30 | -20° | 10.00 | 8.70 | |
|
MUZ-EF25VE/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.57 | -15° | 2.50 | 2.40 | |
|
FDC100VNA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
MUZ-EF42VE/MSZ-EF42VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 3.70 | -15° | 4.20 | 3.80 | |
|
MUZ-FH50VE/MSZ-FH50VE2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.05 | -15° | 5.00 | 4.50 | |
|
RAS-4HVNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.21 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
MUZ-EF25VEH/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
FDC100VNA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
RAS-4HNC2E / RCI-4.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.40 | 4.30 | -20° | 10.00 | 8.70 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
MUZ-FH50VEHZ/MSZ-FH50VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 4.05 | -25° | 5.00 | 6.00 | |
|
MUZ-EF35VE/MSZ-EF35VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.19 | -15° | 3.50 | 2.90 | |
|
FDC100VNA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
MUZ-SF42VE/MSZ-SF42VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.40 | 3.42 | -15° | 4.20 | 3.80 | |
|
MUZ-EF50VE/MSZ-EF50VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.50 | 3.71 | -15° | 5.00 | 4.20 | |
|
MUZ-SF42VEH/MSZ-SF42VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.30 | 3.42 | -20° | 4.20 | 3.80 | |
|
MUZ-GF71VE/MSZ-GF71VE2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.63 | -15° | 7.10 | 6.70 | |
|
MUZ-SF50VE/MSZ-SF50VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 3.41 | -15° | 5.00 | 4.20 | |
|
MUZ-EF35VEH/MSZ-EF35VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.50 | 4.19 | -20° | 3.50 | 2.90 | |
|
RAS-4HNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.96 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
MUZ-SF50VEH/MSZ-SF50VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.41 | -20° | 5.00 | 4.20 | |
|
AOYG36LATT/AUYG36LRLA
AUY**L
|
FUJITSU | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.38 | -15° | 10.00 | 10.00 | |
|
FDC100VNX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.18 | 4.18 | -20° | 10.00 | 11.20 | |
|
RAS-5HVNC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.24 | 3.98 | -20° | 11.90 | 11.93 | |
|
FDC100VNX/SRK50ZSX-W/SRK50ZSX-W
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.16 | 4.31 | -20° | 10.00 | 10.40 | |
|
FDC100VSX/SRK50ZSX-W/SRK50ZSX-W
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.16 | 4.31 | -20° | 10.00 | 10.40 | |
|
FDC100VNA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.84 | 4.17 | 4.18 | -20° | 10.00 | 11.20 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
RAS-5HNC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.13 | 4.23 | 3.98 | -20° | 11.90 | 11.93 |