Filters
| Model | Brand | Type | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|
|
FDC140VNA/FDUM140VH
VNA/VSA (AC2 single)
|
MHI Thermal Systems | Ducted | 5.08 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
MHI Thermal Systems | Ceiling suspended | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDT140VH
VNA-W/VSA-W (AC2 single)
|
MHI Thermal Systems | Cassette | 6.17 | 4.42 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDU140VH
VNA-W/VSA-W (AC2 single)
|
MHI Thermal Systems | Ducted | 5.30 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDUM140VH
VNA-W/VSA-W (AC2 single)
|
MHI Thermal Systems | Ducted | 5.30 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VNX/FDE140VH
VNX/VSX (AC2 single)
|
MHI Thermal Systems | Ceiling suspended | 5.41 | 3.66 | 3.41 | 14.00 | 13.00 | ||
|
FDC140VNX/FDT140VH
VNX/VSX (AC2 single)
|
MHI Thermal Systems | Cassette | 5.97 | 4.06 | 3.81 | 14.00 | 13.00 | ||
|
FDC140VNX/FDU140VH
VNX/VSX (AC2 single)
|
MHI Thermal Systems | Ducted | 5.22 | 3.85 | 3.62 | 14.00 | 13.00 | ||
|
FDC140VNX/FDUM140VH
VNX/VSX (AC2 single)
|
MHI Thermal Systems | Ducted | 5.22 | 3.85 | 3.62 | 14.00 | 13.00 | ||
|
FDC140VSA/FDE140VH
VNA/VSA (AC2 single)
|
MHI Thermal Systems | Ceiling suspended | 5.77 | 4.15 | 3.51 | 13.60 | 10.50 | ||
|
FDC140VSA/FDT140VH
VNA/VSA (AC2 single)
|
MHI Thermal Systems | Cassette | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC140VSA/FDU140VH
VNA/VSA (AC2 single)
|
MHI Thermal Systems | Ducted | 5.08 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA/FDUM140VH
VNA/VSA (AC2 single)
|
MHI Thermal Systems | Ducted | 5.08 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
MHI Thermal Systems | Ceiling suspended | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDT140VH
VNA-W/VSA-W (AC2 single)
|
MHI Thermal Systems | Cassette | 6.14 | 4.42 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDU140VH
VNA-W/VSA-W (AC2 single)
|
MHI Thermal Systems | Ducted | 5.29 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDUM140VH
VNA-W/VSA-W (AC2 single)
|
MHI Thermal Systems | Ducted | 5.30 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSX/FDE140VH
VNX/VSX (AC2 single)
|
MHI Thermal Systems | Ceiling suspended | 5.56 | 3.62 | 3.41 | 14.00 | 15.50 | ||
|
FDC140VSX/FDT140VH
VNX/VSX (AC2 single)
|
MHI Thermal Systems | Cassette | 6.11 | 3.99 | 3.81 | 14.00 | 15.50 | ||
|
FDC140VSX/FDU140VH
VNX/VSX (AC2 single)
|
MHI Thermal Systems | Ducted | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
FDC140VSX/FDUM140VH
VNX/VSX (AC2 single)
|
MHI Thermal Systems | Ducted | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
AOYG45KRTA/ARXG45KMLA
ARXG**K
|
FUJITSU | Ducted | 5.25 | 3.63 | 3.52 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTAP
ARXG**K
|
FUJITSU | Ducted | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG54KRTA/ARXG54KHTAP
ARXG**K
|
FUJITSU | Ducted | 5.81 | 3.85 | 3.98 | 13.40 | 9.50 | ||
|
AOYG45KBTB/AUXG45KRLB
AUXG**K
|
FUJITSU | Cassette | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOYG45KRTA/AUXG45KRLB
AUXG**K
|
FUJITSU | Cassette | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOYG54KBTB/AUXG54KRLB
AUXG**K
|
FUJITSU | Cassette | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOYG54KRTA/AUXG54KRLB
AUXG**K
|
FUJITSU | Cassette | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AZAS125MV1 / FCAG125B
AZAS
|
DAIKIN | Cassette | 5.40 | 3.80 | 12.10 | 6.00 | |||
|
AZAS125MY1 / FCAG125B
AZAS
|
DAIKIN | Cassette | 5.40 | 3.80 | 12.10 | 6.00 | |||
|
AZAS140MV1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
AZAS140MY1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
RZAG125NV1 / FBA125A
RZAG
|
DAIKIN | Ducted | 6.56 | 4.37 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FBA125A
RZAG
|
DAIKIN | Ducted | 6.56 | 4.37 | 12.10 | 9.52 | |||
|
RZAG125NV1 / FHA125A
RZAG
|
DAIKIN | Ceiling suspended | 7.14 | 4.20 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FHA125A
RZAG
|
DAIKIN | Ceiling suspended | 7.14 | 4.20 | 12.10 | 9.52 | |||
|
RZAG125NV1 / FDA125A
RZAG
|
DAIKIN | Ducted | 6.59 | 4.35 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FDA125A
RZAG
|
DAIKIN | Ducted | 6.59 | 4.35 | 12.10 | 9.52 | |||
|
RZAG125NV1 / FCAHG125H
RZAG
|
DAIKIN | Cassette | 8.02 | 4.53 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FCAHG125H
RZAG
|
DAIKIN | Cassette | 8.02 | 4.53 | 12.10 | 9.52 | |||
|
RZAG125NV1 / FCAG125B
RZAG
|
DAIKIN | Cassette | 7.15 | 4.34 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FCAG125B
RZAG
|
DAIKIN | Cassette | 7.15 | 4.34 | 12.10 | 9.52 | |||
|
RZAG125NV1 / FUA125A
RZAG
|
DAIKIN | Ceiling suspended | 6.39 | 4.26 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FUA125A
RZAG
|
DAIKIN | Ceiling suspended | 6.39 | 4.26 | 12.10 | 9.52 | |||
|
RZAG125NV1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
RZAG140NV1 / FBA140A
RZAG
|
DAIKIN | Ducted | 6.42 | 4.34 | 13.40 | 9.52 | |||
|
RZAG140NY1 / FBA140A
RZAG
|
DAIKIN | Ducted | 6.42 | 4.34 | 13.40 | 9.52 | |||
|
RZAG140NV1 / FCAHG140H
RZAG
|
DAIKIN | Cassette | 7.93 | 4.44 | 13.40 | 9.52 | |||
|
RZAG140NY1 / FCAHG140H
RZAG
|
DAIKIN | Cassette | 7.93 | 4.44 | 13.40 | 9.52 |