AR09TXFZBWKN/AR09TXFZBWKX
SAMSUNG - RAC
SEER
A+
SCOP
A+
Certificate:
24.06.004
Model Type:
AC1/A/S/R
Manufacturer:
Samsung Electronics Air Conditioner Europe B.V
Mounting:
Wall mounted
Cooling Performance
PdesigncDesign cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
2.50 kW
SEERSeasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
6.00
EEREnergy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
4.46
PcRated cooling capacity at standard test conditions.
2.50 kW
QceEstimated annual electricity consumption for cooling (kWh/year).
146 kWh
Heating Performance
PdesignhDesign heating capacity at -10°C outdoor (bivalent point). More
2.30 kW
SCOPSeasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.30
COPCoefficient of Performance at +7°C outdoor (standard rated conditions). More
3.95
PhRated heating capacity at standard test conditions.
3.20 kW
QheEstimated annual electricity consumption for heating (kWh/year).
749 kWh
Estimated Annual Running Cost
€
/kWh
Cooling
146 kWh/yr
Heating
749 kWh/yr
StandbyAnnual standby consumption: (Psbc + Psbh) × 8760h / 1000
53 kWh/yr
Total
947 kWh/yr
Heating Partial Load
Cooling Partial Load
Efficiency Ratings
Climate Zone SCOPAverage=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.
SCOP A+
Colder A
Acoustic Levels (dB)Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More
Outdoor
59 dB — Moderate
Indoor 1
56 dB — Moderate
Indoor 2
Operating Limits & Bivalent PointTOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More
TOL (Operating Limit)
-11.0°C
Tbiv (Bivalent Point)
-10.0°C
Ph at TOLHeating capacity at the temperature operating limit.
2.30 kW
COP 2.40
Ph at TbivHeating capacity at the bivalent temperature.
2.30 kW
COP 2.30
TOL -11°
Tbiv -10°
-25°C
-10°C (design)
+7°C (rated)
+20°C
Standby & Off-Mode Power
Cooling Mode
| Standby (Psbc) | 3.0 W |
| Off mode (Poffc) | 3.0 W |
| Thermostat off (Ptoc) | 30.0 W |
| Crankcase heat (Pckc) | 0.0 W |
Heating Mode
| Standby (Psbh) | 3.0 W |
| Off mode (Poffh) | 3.0 W |
| Thermostat off (Ptoh) | 30.0 W |
| Crankcase heat (Pckh) | 0.0 W |
Extended Climate Zone Data
Average Climate
| SCOPSeasonal heating efficiency for the average European climate (design temp −10°C). | 4.30 A+ |
| QheEstimated annual electricity consumption for heating (kWh/year). | 749 kWh |
| ηs,hSeasonal space heating energy efficiency (%). Higher is better. | 0% |
Colder Climate
| SCOPSeasonal heating efficiency for the colder European climate (design temp −22°C). | 3.50 A |
| PdesignhDesign heating capacity for the colder climate zone at −22°C outdoor. | 3.00 kW |
| QheEstimated annual electricity consumption for heating in the colder climate zone (kWh/year). | 1800 kWh |
| ηs,hSeasonal space heating energy efficiency for the colder climate zone (%). | 0% |
| Ph @ TOLHeating capacity at the temperature operating limit (colder climate). | 3.00 kW |
General Specifications
Refrigerant:
R32
Factory ChargePre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
Power Supply:
230-1-50
Capacity ControlFixed=single speed, Variable=inverter-driven modulation. More
Variable
Indoor Units:
1
IU Names:
AR09TXFZBWKN
Pipe Length:
TOLTemperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-11.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
0.56 kW
Peh (Electrical Input Heating):
0.81 kW
Refrigerant Line:
5
CEE Eligible:
true
IU Range Names:
AR09TXFZBWKN