FDC100VSX/FDE50VH/FDE50VH
MHI Thermal Systems - VNX/VSX (AC1 multi)
SEER
A
SCOP
A
Certificate:
17.02.279
Model Type:
AC1/A/M/R
Manufacturer:
MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS Ltd
Mounting:
Ceiling suspended
Cooling Performance
PdesigncDesign cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
10.00 kW
SEERSeasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
5.49
EEREnergy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
3.33
PcRated cooling capacity at standard test conditions.
10.00 kW
QceEstimated annual electricity consumption for cooling (kWh/year).
638 kWh
Heating Performance
PdesignhDesign heating capacity at -10°C outdoor (bivalent point). More
10.80 kW
SCOPSeasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
3.94
COPCoefficient of Performance at +7°C outdoor (standard rated conditions). More
3.30
PhRated heating capacity at standard test conditions.
11.20 kW
QheEstimated annual electricity consumption for heating (kWh/year).
3841 kWh
Estimated Annual Running Cost
€
/kWh
Cooling
638 kWh/yr
Heating
3841 kWh/yr
StandbyAnnual standby consumption: (Psbc + Psbh) × 8760h / 1000
596 kWh/yr
Total
5075 kWh/yr
Heating Partial Load
Cooling Partial Load
Efficiency Ratings
Climate Zone SCOPAverage=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.
SCOP A
Acoustic Levels (dB)Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More
Outdoor
70 dB — Loud
Indoor 1
60 dB — Moderate
Indoor 2
60 dB — Moderate
Operating Limits & Bivalent PointTOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More
TOL (Operating Limit)
-20.0°C
Tbiv (Bivalent Point)
-10.0°C
Ph at TOLHeating capacity at the temperature operating limit.
7.60 kW
COP 2.05
Ph at TbivHeating capacity at the bivalent temperature.
10.80 kW
COP 2.36
TOL -20°
Tbiv -10°
-25°C
-10°C (design)
+7°C (rated)
+20°C
Standby & Off-Mode Power
Cooling Mode
| Standby (Psbc) | 20.0 W |
| Off mode (Poffc) | 20.0 W |
| Thermostat off (Ptoc) | 46.0 W |
| Crankcase heat (Pckc) | 25.0 W |
Heating Mode
| Standby (Psbh) | 48.0 W |
| Off mode (Poffh) | 20.0 W |
| Thermostat off (Ptoh) | 65.0 W |
| Crankcase heat (Pckh) | 25.0 W |
General Specifications
Refrigerant:
R410A
Factory ChargePre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
4.5000
Power Supply:
400-3-50
Capacity ControlFixed=single speed, Variable=inverter-driven modulation. More
Variable
Min Heating LoadLowest continuous output the unit can modulate down to in heating mode. More
36% (1.60 kW)
Indoor Units:
2
IU Names:
FDE50VH
Pipe Length:
30.0000
TOLTemperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-20.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
3.00 kW
Peh (Electrical Input Heating):
3.39 kW
Refrigerant Line:
5
CdDegradation coefficient for cycling losses.
0.25
CEE Eligible:
true
IU Range Names:
FDE-VH