MXZ-2F53VF5/MSZ-LN18VG3/MSZ-LN35VG3
MITSUBISHI ELECTRIC - MXZ series
SEER
A+++
SCOP
A++
Certificate:
94.01.069
Model Type:
AC1/A/M/R
Manufacturer:
MITSUBISHI ELECTRIC air conditioning systems europe ltd
Mounting:
Wall mounted
Cooling Performance
PdesigncDesign cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
5.30 kW
SEERSeasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
8.60
EEREnergy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
3.80
PcRated cooling capacity at standard test conditions.
5.30 kW
QceEstimated annual electricity consumption for cooling (kWh/year).
216 kWh
Heating Performance
PdesignhDesign heating capacity at -10°C outdoor (bivalent point). More
3.50 kW
SCOPSeasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.60
COPCoefficient of Performance at +7°C outdoor (standard rated conditions). More
4.10
PhRated heating capacity at standard test conditions.
6.40 kW
QheEstimated annual electricity consumption for heating (kWh/year).
1065 kWh
Estimated Annual Running Cost
€
/kWh
Cooling
216 kWh/yr
Heating
1065 kWh/yr
StandbyAnnual standby consumption: (Psbc + Psbh) × 8760h / 1000
35 kWh/yr
Total
1316 kWh/yr
Heating Partial Load
Cooling Partial Load
Efficiency Ratings
Climate Zone SCOPAverage=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.
SCOP A++
Acoustic Levels (dB)Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More
Outdoor
61 dB — Moderate
Indoor 1
58 dB — Moderate
Indoor 2
59 dB — Moderate
Operating Limits & Bivalent PointTOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More
TOL (Operating Limit)
-15.0°C
Tbiv (Bivalent Point)
-7.0°C
Ph at TOLHeating capacity at the temperature operating limit.
2.70 kW
COP 2.83
Ph at TbivHeating capacity at the bivalent temperature.
2.90 kW
COP 3.15
TOL -15°
Tbiv -7°
-25°C
-10°C (design)
+7°C (rated)
+20°C
Standby & Off-Mode Power
Cooling Mode
| Standby (Psbc) | 4.0 W |
| Off mode (Poffc) | 4.0 W |
| Thermostat off (Ptoc) | 7.0 W |
| Crankcase heat (Pckc) | 0.0 W |
Heating Mode
| Standby (Psbh) | 0.0 W |
| Off mode (Poffh) | 4.0 W |
| Thermostat off (Ptoh) | 11.0 W |
| Crankcase heat (Pckh) | 0.0 W |
General Specifications
Refrigerant:
R32
Factory ChargePre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
1.0000
Power Supply:
230-1-50
Capacity ControlFixed=single speed, Variable=inverter-driven modulation. More
Variable
Indoor Units:
2
IU Names:
MSZ-LN18VG3/MSZ-LN35VG3
Pipe Length:
30.0000
TOLTemperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-15.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
1.39 kW
Peh (Electrical Input Heating):
1.56 kW
Refrigerant Line:
5mx2
CEE Eligible:
true
IU Range Names:
MSZ