← Back to list

RAM-G70N4HAE / RAK-XJ35RHAE / RAK-XJ35RHAE

HITACHI - RAM-GNHAE

SEER
A++
SCOP
A++
Certificate: 05.01.199
Model Type: AC1/A/M/R
Manufacturer: JOHNSON CONTROLS-HITACHI AIR CONDITIONING SPAIN S.A.U.
Mounting: Wall mounted

Cooling Performance

Pdesignc?Design cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
7.00 kW
SEER?Seasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
7.39
EER?Energy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
3.29
Pc?Rated cooling capacity at standard test conditions.
7.00 kW
Qce?Estimated annual electricity consumption for cooling (kWh/year).
332 kWh

Heating Performance

Pdesignh?Design heating capacity at -10°C outdoor (bivalent point). More
5.90 kW
SCOP?Seasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.62
COP?Coefficient of Performance at +7°C outdoor (standard rated conditions). More
4.20
Ph?Rated heating capacity at standard test conditions.
8.50 kW
Qhe?Estimated annual electricity consumption for heating (kWh/year).
1788 kWh

Estimated Annual Running Cost

/kWh
Cooling
332 kWh/yr
Heating
1788 kWh/yr
Standby?Annual standby consumption: (Psbc + Psbh) × 8760h / 1000
70 kWh/yr
Total
2190 kWh/yr

Heating Partial Load

Cooling Partial Load

Efficiency Ratings

Climate Zone SCOP?Average=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.

SCOP A++ Colder B Warmer A+++

Acoustic Levels (dB)?Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More

Outdoor
65 dB — Loud
Indoor 1
60 dB — Moderate
Indoor 2
60 dB — Moderate

Operating Limits & Bivalent Point?TOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More

TOL (Operating Limit)
-15.0°C
Tbiv (Bivalent Point)
-7.0°C
Ph at TOL?Heating capacity at the temperature operating limit.
5.63 kW
COP 2.66
Ph at Tbiv?Heating capacity at the bivalent temperature.
5.22 kW
COP 3.03
TOL -15°
Tbiv -7°
-25°C -10°C (design) +7°C (rated) +20°C
Standby & Off-Mode Power

Cooling Mode

Standby (Psbc)4.0 W
Off mode (Poffc)4.0 W
Thermostat off (Ptoc)9.0 W
Crankcase heat (Pckc)0.0 W

Heating Mode

Standby (Psbh)4.0 W
Off mode (Poffh)4.0 W
Thermostat off (Ptoh)9.0 W
Crankcase heat (Pckh)0.0 W
Extended Climate Zone Data

Average Climate

SCOP?Seasonal heating efficiency for the average European climate (design temp −10°C).4.62 A++
Qhe?Estimated annual electricity consumption for heating (kWh/year).1788 kWh
ηs,h?Seasonal space heating energy efficiency (%). Higher is better.0%

Colder Climate

SCOP?Seasonal heating efficiency for the colder European climate (design temp −22°C).3.38 B
Pdesignh?Design heating capacity for the colder climate zone at −22°C outdoor.8.62 kW
Qhe?Estimated annual electricity consumption for heating in the colder climate zone (kWh/year).5359 kWh
ηs,h?Seasonal space heating energy efficiency for the colder climate zone (%).0%
COP @ +7°C?Heating efficiency at +7°C outdoor, 24% part load (colder climate point C).6.04
COP @ +12°C?Heating efficiency at +12°C outdoor, 11% part load (colder climate point D).7.86
Ph @ +12°C?Heating capacity at +12°C outdoor, 11% part load (colder climate).2.26 kW
Ph @ TOL?Heating capacity at the temperature operating limit (colder climate).5.32 kW

Warmer Climate

SCOP?Seasonal heating efficiency for the warmer European climate (design temp +2°C).6.19 A+++
Qhe?Estimated annual electricity consumption for heating in the warmer climate zone (kWh/year).719 kWh
ηs,h?Seasonal space heating energy efficiency for the warmer climate zone (%).0%

General Specifications

Refrigerant:
R32
Factory Charge?Pre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
2.0500
Power Supply:
230-1-50
Capacity Control?Fixed=single speed, Variable=inverter-driven modulation. More
Variable
Indoor Units:
2
IU Names:
RAK-XJ35RHAE / RAK-XJ35RHAE
Pipe Length:
5.0000
TOL?Temperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-15.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
2.13 kW
Peh (Electrical Input Heating):
2.02 kW
Refrigerant Line:
5
CEE Eligible:
true
IU Range Names:
EV

Similar Devices