← Back to list

RXA35A8 / FTXA35CB

DAIKIN - RXA

SEER
A+++
SCOP
A+++
Certificate: 94.01.087
Model Type: AC1/A/S/R
Manufacturer: DAIKIN EUROPE NV
Mounting: Wall mounted

Cooling Performance

Pdesignc?Design cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
3.40 kW
SEER?Seasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
8.73
EER?Energy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
4.37
Pc?Rated cooling capacity at standard test conditions.
3.40 kW
Qce?Estimated annual electricity consumption for cooling (kWh/year).
136 kWh

Heating Performance

Pdesignh?Design heating capacity at -10°C outdoor (bivalent point). More
2.50 kW
SCOP?Seasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
5.15
COP?Coefficient of Performance at +7°C outdoor (standard rated conditions). More
4.04
Ph?Rated heating capacity at standard test conditions.
4.00 kW
Qhe?Estimated annual electricity consumption for heating (kWh/year).
680 kWh

Estimated Annual Running Cost

/kWh
Cooling
136 kWh/yr
Heating
680 kWh/yr
Standby?Annual standby consumption: (Psbc + Psbh) × 8760h / 1000
18 kWh/yr
Total
834 kWh/yr

Heating Partial Load

Cooling Partial Load

Efficiency Ratings

Climate Zone SCOP?Average=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.

SCOP A+++

Acoustic Levels (dB)?Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More

Outdoor
61 dB — Moderate
Indoor 1
60 dB — Moderate
Indoor 2

Operating Limits & Bivalent Point?TOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More

TOL (Operating Limit)
-10.0°C
Tbiv (Bivalent Point)
-7.0°C
Ph at TOL?Heating capacity at the temperature operating limit.
2.10 kW
COP 3.20
Ph at Tbiv?Heating capacity at the bivalent temperature.
2.22 kW
COP 3.58
TOL -10°
Tbiv -7°
-25°C -10°C (design) +7°C (rated) +20°C
Standby & Off-Mode Power

Cooling Mode

Standby (Psbc)1.0 W
Off mode (Poffc)1.0 W
Thermostat off (Ptoc)7.0 W
Crankcase heat (Pckc)0.0 W

Heating Mode

Standby (Psbh)1.0 W
Off mode (Poffh)1.0 W
Thermostat off (Ptoh)13.0 W
Crankcase heat (Pckh)0.0 W

General Specifications

Refrigerant:
R32
Factory Charge?Pre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
0.7600
Power Supply:
230-1-50
Capacity Control?Fixed=single speed, Variable=inverter-driven modulation. More
variable
Min Cooling Load?Lowest continuous output the unit can modulate down to in cooling mode. More
40% (2.31 kW)
Min Heating Load?Lowest continuous output the unit can modulate down to in heating mode. More
24% (1.59 kW)
Indoor Units:
1
IU Names:
FTXA35CB
Pipe Length:
10.0000
TOL?Temperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-10.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
0.78 kW
Peh (Electrical Input Heating):
0.99 kW
Refrigerant Line:
5
CEE Eligible:
true