← Back to list

RZAG71NV1 / FHA35A9 / FHA35A9

DAIKIN - RZAG

SEER
A++
SCOP
A+
Certificate: 94.01.087
Model Type: AC1/A/M/R
Manufacturer: DAIKIN EUROPE NV
Mounting: Ceiling suspended

Cooling Performance

Pdesignc?Design cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
6.80 kW
SEER?Seasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
7.80
EER?Energy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
4.44
Pc?Rated cooling capacity at standard test conditions.
6.80 kW
Qce?Estimated annual electricity consumption for cooling (kWh/year).
305 kWh

Heating Performance

Pdesignh?Design heating capacity at -10°C outdoor (bivalent point). More
4.70 kW
SCOP?Seasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.42
COP?Coefficient of Performance at +7°C outdoor (standard rated conditions). More
4.42
Ph?Rated heating capacity at standard test conditions.
7.50 kW
Qhe?Estimated annual electricity consumption for heating (kWh/year).
1488 kWh

Estimated Annual Running Cost

/kWh
Cooling
305 kWh/yr
Heating
1488 kWh/yr
Standby?Annual standby consumption: (Psbc + Psbh) × 8760h / 1000
105 kWh/yr
Total
1898 kWh/yr

Heating Partial Load

Cooling Partial Load

Efficiency Ratings

Climate Zone SCOP?Average=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.

SCOP A+

Acoustic Levels (dB)?Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More

Outdoor
64 dB — Moderate
Indoor 1
53 dB — Quiet
Indoor 2

Operating Limits & Bivalent Point?TOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More

TOL (Operating Limit)
-10.0°C
Tbiv (Bivalent Point)
-10.0°C
Ph at TOL?Heating capacity at the temperature operating limit.
4.70 kW
COP 2.98
Ph at Tbiv?Heating capacity at the bivalent temperature.
4.70 kW
COP 2.98
TOL -10°
Tbiv -10°
-25°C -10°C (design) +7°C (rated) +20°C
Standby & Off-Mode Power

Cooling Mode

Standby (Psbc)12.0 W
Off mode (Poffc)12.0 W
Thermostat off (Ptoc)5.0 W
Crankcase heat (Pckc)0.0 W

Heating Mode

Standby (Psbh)0.0 W
Off mode (Poffh)12.0 W
Thermostat off (Ptoh)16.0 W
Crankcase heat (Pckh)0.0 W

General Specifications

Refrigerant:
R32
Factory Charge?Pre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
3.2000
Power Supply:
230-1-50
Capacity Control?Fixed=single speed, Variable=inverter-driven modulation. More
variable
Min Cooling Load?Lowest continuous output the unit can modulate down to in cooling mode. More
40% (2.23 kW)
Min Heating Load?Lowest continuous output the unit can modulate down to in heating mode. More
25% (1.15 kW)
Indoor Units:
2
IU Names:
FHA35A9 / FHA35A9
Pipe Length:
40.0000
TOL?Temperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-10.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
1.53 kW
Peh (Electrical Input Heating):
1.70 kW
Refrigerant Line:
5 m
CEE Eligible:
true