RZAG71NV1 / FNA35A9 / FNA35A9
DAIKIN - RZAG
SEER
A++
SCOP
A+
Certificate:
94.01.087
Model Type:
AC1/A/M/R
Manufacturer:
DAIKIN EUROPE NV
Mounting:
Ducted
Cooling Performance
PdesigncDesign cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
6.80 kW
SEERSeasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
6.55
EEREnergy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
4.04
PcRated cooling capacity at standard test conditions.
6.80 kW
QceEstimated annual electricity consumption for cooling (kWh/year).
363 kWh
Heating Performance
PdesignhDesign heating capacity at -10°C outdoor (bivalent point). More
4.70 kW
SCOPSeasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.14
COPCoefficient of Performance at +7°C outdoor (standard rated conditions). More
4.14
PhRated heating capacity at standard test conditions.
7.50 kW
QheEstimated annual electricity consumption for heating (kWh/year).
1591 kWh
Estimated Annual Running Cost
€
/kWh
Cooling
363 kWh/yr
Heating
1591 kWh/yr
StandbyAnnual standby consumption: (Psbc + Psbh) × 8760h / 1000
149 kWh/yr
Total
2103 kWh/yr
Heating Partial Load
Cooling Partial Load
Efficiency Ratings
Climate Zone SCOPAverage=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.
SCOP A+
Acoustic Levels (dB)Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More
Outdoor
64 dB — Moderate
Indoor 1
Indoor 2
Operating Limits & Bivalent PointTOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More
TOL (Operating Limit)
-10.0°C
Tbiv (Bivalent Point)
-10.0°C
Ph at TOLHeating capacity at the temperature operating limit.
4.70 kW
COP 2.69
Ph at TbivHeating capacity at the bivalent temperature.
4.70 kW
COP 2.69
TOL -10°
Tbiv -10°
-25°C
-10°C (design)
+7°C (rated)
+20°C
Standby & Off-Mode Power
Cooling Mode
| Standby (Psbc) | 17.0 W |
| Off mode (Poffc) | 17.0 W |
| Thermostat off (Ptoc) | 5.0 W |
| Crankcase heat (Pckc) | 0.0 W |
Heating Mode
| Standby (Psbh) | 0.0 W |
| Off mode (Poffh) | 17.0 W |
| Thermostat off (Ptoh) | 21.0 W |
| Crankcase heat (Pckh) | 0.0 W |
General Specifications
Refrigerant:
R32
Factory ChargePre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
3.2000
Power Supply:
230-1-50
Capacity ControlFixed=single speed, Variable=inverter-driven modulation. More
variable
Min Cooling LoadLowest continuous output the unit can modulate down to in cooling mode. More
40% (2.14 kW)
Min Heating LoadLowest continuous output the unit can modulate down to in heating mode. More
24% (1.22 kW)
Indoor Units:
2
IU Names:
FNA35A9 / FNA35A9
Pipe Length:
40.0000
TOLTemperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-10.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
1.68 kW
Peh (Electrical Input Heating):
1.81 kW
Refrigerant Line:
5 m
CEE Eligible:
true
IU Range Names:
FNA