← Back to list

AJ100TXJ5KH / AJ050TNAPKH / AJ050TNAPKH

SAMSUNG - FJM

SEER
A
SCOP
A
Certificate: 24.06.004
Model Type: AC1/A/M/R
Manufacturer: Samsung Electronics Air Conditioner Europe B.V
Mounting: Wall mounted

Cooling Performance

Pdesignc?Design cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
8.56 kW
SEER?Seasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
5.51
EER?Energy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
3.23
Pc?Rated cooling capacity at standard test conditions.
8.56 kW
Qce?Estimated annual electricity consumption for cooling (kWh/year).
544 kWh

Heating Performance

Pdesignh?Design heating capacity at -10°C outdoor (bivalent point). More
7.70 kW
SCOP?Seasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
3.83
COP?Coefficient of Performance at +7°C outdoor (standard rated conditions). More
3.63
Ph?Rated heating capacity at standard test conditions.
10.60 kW
Qhe?Estimated annual electricity consumption for heating (kWh/year).
2812 kWh

Estimated Annual Running Cost

/kWh
Cooling
544 kWh/yr
Heating
2812 kWh/yr
Standby?Annual standby consumption: (Psbc + Psbh) × 8760h / 1000
210 kWh/yr
Total
3566 kWh/yr

Heating Partial Load

Cooling Partial Load

Efficiency Ratings

Climate Zone SCOP?Average=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.

SCOP A

Acoustic Levels (dB)?Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More

Outdoor
70 dB — Loud
Indoor 1
58 dB — Moderate
Indoor 2
58 dB — Moderate

Operating Limits & Bivalent Point?TOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More

TOL (Operating Limit)
-10.0°C
Tbiv (Bivalent Point)
-7.0°C
Ph at TOL?Heating capacity at the temperature operating limit.
7.60 kW
COP 2.40
Ph at Tbiv?Heating capacity at the bivalent temperature.
6.81 kW
COP 2.69
TOL -10°
Tbiv -7°
-25°C -10°C (design) +7°C (rated) +20°C
Standby & Off-Mode Power

Cooling Mode

Standby (Psbc)12.0 W
Off mode (Poffc)12.0 W
Thermostat off (Ptoc)100.0 W
Crankcase heat (Pckc)0.0 W

Heating Mode

Standby (Psbh)12.0 W
Off mode (Poffh)12.0 W
Thermostat off (Ptoh)100.0 W
Crankcase heat (Pckh)0.0 W

General Specifications

Refrigerant:
R410A
Factory Charge?Pre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
Power Supply:
230-1-50
Capacity Control?Fixed=single speed, Variable=inverter-driven modulation. More
Variable
Indoor Units:
2
IU Names:
AJ050TNAPKH / AJ050TNAPKH
Pipe Length:
TOL?Temperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-10.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
2.65 kW
Peh (Electrical Input Heating):
2.92 kW
Refrigerant Line:
5
CEE Eligible:
false
IU Range Names:
AJ050TNAPKH / AJ050TNAPKH