RAC-VJ50NHAE / RAI-VJ50RHAE
HITACHI - RAC-VJ-NHAE airHome Mono Multi Universal
SEER
A++
SCOP
A+
Certificate:
05.01.199
Model Type:
AC1/A/S/R
Manufacturer:
JOHNSON CONTROLS-HITACHI AIR CONDITIONING SPAIN S.A.U.
Mounting:
Cassette
Cooling Performance
PdesigncDesign cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
5.00 kW
SEERSeasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
6.90
EEREnergy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
3.50
PcRated cooling capacity at standard test conditions.
5.00 kW
QceEstimated annual electricity consumption for cooling (kWh/year).
253 kWh
Heating Performance
PdesignhDesign heating capacity at -10°C outdoor (bivalent point). More
4.30 kW
SCOPSeasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.11
COPCoefficient of Performance at +7°C outdoor (standard rated conditions). More
3.72
PhRated heating capacity at standard test conditions.
6.00 kW
QheEstimated annual electricity consumption for heating (kWh/year).
1466 kWh
Estimated Annual Running Cost
€
/kWh
Cooling
253 kWh/yr
Heating
1466 kWh/yr
StandbyAnnual standby consumption: (Psbc + Psbh) × 8760h / 1000
70 kWh/yr
Total
1789 kWh/yr
Heating Partial Load
Cooling Partial Load
Efficiency Ratings
Climate Zone SCOPAverage=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.
SCOP A+
Colder C
Warmer A+++
Acoustic Levels (dB)Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More
Outdoor
65 dB — Loud
Indoor 1
56 dB — Moderate
Indoor 2
Operating Limits & Bivalent PointTOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More
TOL (Operating Limit)
-10.0°C
Tbiv (Bivalent Point)
-7.0°C
Ph at TOLHeating capacity at the temperature operating limit.
4.30 kW
COP 1.99
Ph at TbivHeating capacity at the bivalent temperature.
3.80 kW
COP 2.74
TOL -10°
Tbiv -7°
-25°C
-10°C (design)
+7°C (rated)
+20°C
Note: This unit declares colder-climate performance at −15°C (COP 1.99) despite a TOL of -10°C. The declared TOL may be conservative — the unit likely operates below it at reduced efficiency.
Standby & Off-Mode Power
Cooling Mode
| Standby (Psbc) | 4.0 W |
| Off mode (Poffc) | 4.0 W |
| Thermostat off (Ptoc) | 17.0 W |
| Crankcase heat (Pckc) | 0.0 W |
Heating Mode
| Standby (Psbh) | 4.0 W |
| Off mode (Poffh) | 4.0 W |
| Thermostat off (Ptoh) | 17.0 W |
| Crankcase heat (Pckh) | 0.0 W |
Extended Climate Zone Data
Average Climate
| SCOPSeasonal heating efficiency for the average European climate (design temp −10°C). | 4.11 A+ |
| QheEstimated annual electricity consumption for heating (kWh/year). | 1466 kWh |
| ηs,hSeasonal space heating energy efficiency (%). Higher is better. | 0% |
Colder Climate
| SCOPSeasonal heating efficiency for the colder European climate (design temp −22°C). | 3.04 C |
| PdesignhDesign heating capacity for the colder climate zone at −22°C outdoor. | 6.28 kW |
| QheEstimated annual electricity consumption for heating in the colder climate zone (kWh/year). | 4349 kWh |
| ηs,hSeasonal space heating energy efficiency for the colder climate zone (%). | 0% |
| COP @ +7°CHeating efficiency at +7°C outdoor, 24% part load (colder climate point C). | 5.96 |
| COP @ +12°CHeating efficiency at +12°C outdoor, 11% part load (colder climate point D). | 7.49 |
| Ph @ +12°CHeating capacity at +12°C outdoor, 11% part load (colder climate). | 1.58 kW |
| Ph @ TOLHeating capacity at the temperature operating limit (colder climate). | 4.30 kW |
Warmer Climate
| SCOPSeasonal heating efficiency for the warmer European climate (design temp +2°C). | 5.77 A+++ |
| QheEstimated annual electricity consumption for heating in the warmer climate zone (kWh/year). | 562 kWh |
| ηs,hSeasonal space heating energy efficiency for the warmer climate zone (%). | 0% |
General Specifications
Refrigerant:
R32
Factory ChargePre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
1.3000
Power Supply:
230
Capacity ControlFixed=single speed, Variable=inverter-driven modulation. More
Variable
Indoor Units:
1
IU Names:
RAI-VJ50RHAE
Pipe Length:
5.0000
TOLTemperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-10.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
1.43 kW
Peh (Electrical Input Heating):
1.61 kW
Refrigerant Line:
5
CEE Eligible:
true
IU Range Names:
EV